Internet Engineering Task Force (IETF) M. Bakke Request for Comments: 7147 Dell Obsoletes: 4544 P. Venkatesen Category: Standards Track HCL Technologies ISSN: 2070-1721 April 2014 Definitions of Managed Objects for the Internet Small Computer System Interface (iSCSI) Abstract This document defines a portion of the Management Information Base (MIB) for use with network management protocols. In particular, it defines objects for managing a client using the Internet Small Computer System Interface (iSCSI) protocol (SCSI over TCP). This document obsoletes RFC 4544. Status of This Memo This is an Internet Standards Track document. This document is a product of the Internet Engineering Task Force (IETF). It represents the consensus of the IETF community. It has received public review and has been approved for publication by the Internet Engineering Steering Group (IESG). Further information on Internet Standards is available in Section 2 of RFC 5741. Information about the current status of this document, any errata, and how to provide feedback on it may be obtained at http://www.rfc-editor.org/info/rfc7147. Bakke & Venkatesen Standards Track [Page 1] RFC 7147 iSCSI MIB April 2014 Copyright Notice Copyright (c) 2014 IETF Trust and the persons identified as the document authors. All rights reserved. This document is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info) in effect on the date of publication of this document. Please review these documents carefully, as they describe your rights and restrictions with respect to this document. Code Components extracted from this document must include Simplified BSD License text as described in Section 4.e of the Trust Legal Provisions and are provided without warranty as described in the Simplified BSD License. This document may contain material from IETF Documents or IETF Contributions published or made publicly available before November 10, 2008. The person(s) controlling the copyright in some of this material may not have granted the IETF Trust the right to allow modifications of such material outside the IETF Standards Process. Without obtaining an adequate license from the person(s) controlling the copyright in such materials, this document may not be modified outside the IETF Standards Process, and derivative works of it may not be created outside the IETF Standards Process, except to format it for publication as an RFC or to translate it into languages other than English. Bakke & Venkatesen Standards Track [Page 2] RFC 7147 iSCSI MIB April 2014 Table of Contents 1. The Internet-Standard Management Framework ......................4 2. Introduction ....................................................4 3. Relationship to Other MIB Modules ...............................4 4. Relationship to SNMP Contexts ...................................5 5. Differences from RFC 4544 .......................................5 6. Discussion ......................................................6 6.1. iSCSI MIB Object Model .....................................7 6.2. iSCSI MIB Table Structure ..................................8 6.3. iscsiInstance ..............................................9 6.4. iscsiPortal ................................................9 6.5. iscsiTargetPortal .........................................10 6.6. iscsiInitiatorPortal ......................................11 6.7. iscsiNode .................................................12 6.8. iscsiTarget ...............................................12 6.9. iscsiTgtAuthorization .....................................12 6.10. iscsiInitiator ...........................................13 6.11. iscsiIntrAuthorization ...................................13 6.12. iscsiSession .............................................13 6.13. iscsiConnection ..........................................14 6.14. IP Addresses and TCP Port Numbers ........................14 6.15. Descriptors: Using OIDs in Place of Enumerated Types .....15 6.16. Notifications ............................................15 7. MIB Definition .................................................16 8. Security Considerations ........................................88 9. IANA Considerations ............................................89 10. References ....................................................89 10.1. Normative References .....................................89 10.2. Informative References ...................................91 11. Acknowledgments ...............................................91 Bakke & Venkatesen Standards Track [Page 3] RFC 7147 iSCSI MIB April 2014 1. The Internet-Standard Management Framework For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to section 7 of RFC 3410 [RFC3410]. Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580 [RFC2580]. 2. Introduction This document defines a MIB module for iSCSI [RFC7143], used to manage devices that implement the iSCSI protocol. It obsoletes RFC 4544 [RFC4544]. The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in [RFC2119]. 3. Relationship to Other MIB Modules The iSCSI MIB module is normally layered between the SCSI MIB module [RFC4455] and the TCP MIB module [RFC4022], and it makes use of the IP Storage (IPS) Identity Authentication MIB module [RFC4545]. Here is how these modules are related: SCSI MIB Within systems where a SCSI layer is present, each iscsiNode, whether it has an initiator role, target role, or both, is related to one SCSI device within the SCSI MIB module. In this case, the iscsiNodeTransportType attribute points to the SCSI transport object within the SCSI MIB module, which in turn contains an attribute that points back to the iscsiNode. In this way, a management station can navigate between the two MIB modules. In systems where a SCSI layer is not present, such as within an iSCSI proxy device, the iscsiNodeTransportType attribute points to the appropriate corresponding object within the appropriate MIB or is left blank. Bakke & Venkatesen Standards Track [Page 4] RFC 7147 iSCSI MIB April 2014 TCP MIB Each iSCSI connection is related to one transport-level connection. Currently, iSCSI uses only TCP; the iSCSI connection is related to a TCP connection using its normal (protocol, source address, source port, destination address, destination port) 5-tuple. AUTH MIB Each iSCSI node that serves a target role can have a list of authorized initiators. Each of the entries in this list points to an identity within the IPS Identity Authentication MIB module that will be allowed to access the target. iSCSI nodes that serve in an initiator role can also have a list of authorized targets. Each of the entries in this list points to an identity within the IPS-AUTH MIB module to which the initiator should attempt to establish sessions. The IPS-AUTH MIB module includes information used to identify initiators and targets by their iSCSI name, IP address, and/or credentials. This MIB module imports objects from RFCs 2578 [RFC2578], 2579 [RFC2579], 2580 [RFC2580], and 3411 [RFC3411]. It also imports textual conventions from the INET-ADDRESS-MIB [RFC4001]. 4. Relationship to SNMP Contexts Each non-scalar object in the iSCSI MIB module is indexed first by an iSCSI instance. Each instance is a collection of nodes, portals, sessions, etc., that can define a physical or virtual partitioning of an iSCSI-capable device. The use of an instance works well with partitionable or hierarchical storage devices and fits in logically with other management schemes. Instances do not replace SNMP contexts; however, they do provide a very simple way to assign a virtual or physical partition of a device to one or more SNMP contexts, without having to do so for each individual node, portal, and session row. 5. Differences from RFC 4544 [RFC7143] updates several RFCs, including [RFC3720]. This document updates the iSCSI MIB correspondingly. The document uses iSCSIProtocolLevel as defined in [RFC7144]. It obsoletes [RFC4544]. Below is a brief description of the changes. - Added iscsiInstXNodeArchitecture to InstanceAttributes. - Added iscsiSsnTaskReporting of type BITS to SessionAttributes. - Added iscsiSsnProtocolLevel to SessionAttributes. - Deprecated the marker objects. - Fixed the errata to [RFC4544]. Bakke & Venkatesen Standards Track [Page 5] RFC 7147 iSCSI MIB April 2014 - Added NOP counters at iSCSI session scope for heartbeat tracking. - Added port number to the iscsiTgtLoginFailure and iscsiIntrLoginFailure notifications, and to the last failure info in iscsiInitiatorAttributesEntry. - Added description string to the iSCSI portal. - Added iscsiInstSsnTgtUnmappedErrors to support "Target Unmapped" session failure reporting in the iscsiInstSessionFailure notification. - Added iscsiTgtLogoutCxnClosed and iscsiTgtLogoutCxnRemoved, which maintain the count of Logout Command PDUs received by the target with reason codes 1 and 2, respectively. - Changed the conformance statements to match the above. 6. Discussion This MIB module structure supplies configuration, fault, and statistics information for iSCSI devices [RFC7143]. It is structured around the well-known iSCSI objects, such as targets, initiators, sessions, connections, and the like. This MIB module may also be used to configure access to iSCSI targets, by creating iSCSI portals and authorization list entries. It is worthwhile to note that this is an iSCSI MIB module and as such reflects only iSCSI objects. This module does not contain information about the SCSI-layer attributes of a device. If a SCSI layer is present, the SCSI MIB module [RFC4455] may be used to manage SCSI information for a device. The iSCSI MIB module consists of several "objects", each of which is represented by one or more tables. This section contains a brief description of the object hierarchy and a description of each object, followed by a discussion of the actual table structure within the objects. Bakke & Venkatesen Standards Track [Page 6] RFC 7147 iSCSI MIB April 2014 6.1. iSCSI MIB Object Model The top-level object in this structure is the iSCSI instance, which "contains" all of the other objects. iscsiInstance -- A distinct iSCSI entity within the managed system. iscsiPortal -- An IP address used by this instance. iscsiTargetPortal -- Contains portal information relevant when the portal -- is used to listen for connections to its targets. iscsiInitiatorPortal -- Contains portal information relevant when the portal -- is used to initiate connections to other targets. iscsiNode -- An iSCSI node can act as an initiator, a target, or both. -- Contains generic (non-role-specific) information. iscsiTarget -- Target-specific iSCSI node information. iscsiTgtAuth -- A list of initiator identities that are allowed -- access to this target. iscsiInitiator -- Initiator-specific iSCSI node information. iscsiIntrAuth -- A list of target identities to which this initiator -- is configured to establish sessions. iscsiSession -- An active iSCSI session between an initiator and -- target. The session's direction may be Inbound -- (an outside initiator to the target represented by -- this node) or Outbound (the initiator represented by -- this node to an outside target). iscsiConnection -- An active TCP connection within an iSCSI session. An iSCSI node can be an initiator, a target, or both. The iSCSI node's portals may be used to initiate connections (initiator) or listen for connections (target), depending on whether the iSCSI node is acting as an initiator or target. The iSCSI MIB module assumes that any target may be accessed via any portal that can take on a target role, although other access controls not reflected in the module might limit this. Bakke & Venkatesen Standards Track [Page 7] RFC 7147 iSCSI MIB April 2014 6.2. iSCSI MIB Table Structure Each iSCSI object exports one or more tables: an attributes table, and zero or more statistics tables, which augment the attributes table. Since iSCSI is an evolving standard, it is much cleaner to provide statistics and attributes as separate tables, allowing attributes and statistics to be added independently. In a few cases, there are multiple categories of statistics that will likely grow; in this case, an object will contain multiple statistics tables. iscsiObjects iscsiDescriptors iscsiInstance iscsiInstanceAttributesTable iscsiInstanceSsnErrorStatsTable -- Counts abnormal session terminations iscsiPortal iscsiPortalAttributesTable iscsiTargetPortal iscsiTgtPortalAttributesTable iscsiInitiatorPortal iscsiIntrPortalAttributesTable iscsiNode iscsiNodeAttributesTable iscsiTarget iscsiTargetAttributesTable iscsiTargetLoginStatsTable -- Counts successful and unsuccessful logins iscsiTargetLogoutStatsTable -- Counts normal and abnormal logouts iscsiTgtAuthorization iscsiTgtAuthAttributesTable iscsiInitiator iscsiInitiatorAttributesTable iscsiInitiatorLoginStatsTable -- Counts successful and unsuccessful logins iscsiInitiatorLogoutStatsTable -- Counts normal and abnormal logouts iscsiIntrAuthorization iscsiIntrAuthAttributesTable iscsiSession iscsiSessionAttributesTable iscsiSessionStatsTable -- Performance-related counts (requests, responses, bytes) iscsiSessionCxnErrorStatsTable -- Counts digest errors, connection errors, etc. iscsiConnection iscsiConnectionAttributesTable Bakke & Venkatesen Standards Track [Page 8] RFC 7147 iSCSI MIB April 2014 Note that this module does not attempt to count everything that could be counted; it is designed to include only those counters that would be useful for identifying performance, security, and fault problems from a management station. 6.3. iscsiInstance The iscsiInstanceAttributesTable is the primary table of the iSCSI MIB module. Every table entry in this module is "owned" by exactly one iSCSI instance; all other table entries in the module include this table's index as their primary index. Most implementations will include just one iSCSI instance row in this table. However, this table exists to allow for multiple virtual instances. For example, many IP routing products now allow multiple virtual routers. The iSCSI MIB module has the same premise; a large system could be "partitioned" into multiple, distinct virtual systems. This also allows a single SNMP agent to proxy for multiple subsystems, perhaps a set of stackable devices, each of which has one or even more instances. The instance attributes include the iSCSI vendor and version, as well as information on the last target or initiator at the other end of a session that caused a session failure. The iscsiInstanceSsnErrorStatsTable augments the attributes table and provides statistics on session failures due to digest, connection, or iSCSI format errors. 6.4. iscsiPortal The iscsiPortalAttributesTable lists iSCSI portals that can be used to listen for connections to targets, to initiate connections to other targets, or to do both. Each row in the table includes an IP address (either v4 or v6), and a transport protocol (currently only TCP is defined). Each portal may have additional attributes, depending on whether it is an initiator portal, a target portal, or both. Initiator portals also have portal tags; these are placed in corresponding rows in the iscsiIntrPortalAttributesTable. Target portals have both portal tags and ports (e.g., TCP listen ports if the transport protocol is TCP); these are placed in rows in the iscsiTgtPortalAttributesTable. Bakke & Venkatesen Standards Track [Page 9] RFC 7147 iSCSI MIB April 2014 Portal rows, along with their initiator and target portal counterparts, may be created and destroyed through this MIB module by a management station. Rows in the initiator and target portal tables are created and destroyed automatically by the agent when a row is created or destroyed in the iscsiPortalAttributesTable or when the value of iscsiPortalRoles changes. Attributes in these tables may then be modified by the management station if the agent implementation allows. When created by a management station, the iscsiPortalRoles attribute is used to control row creation in the initiator and target portal tables. Creating a row with the targetTypePortal bit set in iscsiPortalRoles will cause the implementation to start listening for iSCSI connections on the portal. Creating a row with the initiatorTypePortal bit set in iscsiPortalRoles will not necessarily cause connections to be established; it is left to the implementation whether and when to make use of the portal. Both bits may be set if the portal is to be used by both initiator and target nodes. When deleting a row in the iscsiPortalAttibutesTable, all connections associated with that row are terminated. The implementation may either terminate the connection immediately or request a clean shutdown as specified in [RFC7143]. An outbound connection (when an iscsiInitiatorPortal is deleted) matches the portal if its iscsiCxnLocalAddr matches the iscsiPortalAddr. An inbound connection (when an iscsiTargetPortal is deleted) matches the portal if its iscsiCxnLocalAddr matches the iscsiPortalAddr and if its iscsiCxnLocalPort matches the iscsiTargetPortalPort. Individual objects within a row in this table may not be modified while the row is active. For instance, changing the IP address of a portal requires that the rows associated with the old IP address be deleted and that new rows be created (in either order). 6.5. iscsiTargetPortal The iscsiTgtPortalAttributesTable contains target-specific attributes for iSCSI portals. Rows in this table use the same indices as their corresponding rows in the iscsiPortalAttributesTable, with the addition of iscsiNodeIndex. Rows in this table are created when the targetTypePortal bit is set in the iscsiPortalRoles attribute of the corresponding iscsiPortalAttributesEntry; they are destroyed when this bit is cleared. Bakke & Venkatesen Standards Track [Page 10] RFC 7147 iSCSI MIB April 2014 This table contains the TCP (or other protocol) port on which the socket is listening for incoming connections. It also includes a portal group aggregation tag; iSCSI target portals that are within this instance and share the same tag can contain connections within the same session. This table will be empty for iSCSI instances that contain only initiators (such as iSCSI host driver implementations). Many implementations use the same Target Portal Group Tag and protocol port for all nodes accessed via a portal. These implementations will create a single row in the iscsiTgtPortalAttributeTable, with an iscsiNodeIndex of zero. Other implementations do not use the same tag and/or port for all nodes; these implementations will create a row in this table for each (portal, node) tuple, using iscsiNodeIndex to designate the node for this portal tag and port. 6.6. iscsiInitiatorPortal The iscsiIntrPortalAttributesTable contains initiator-specific objects for iSCSI portals. Rows in this table use the same indices as their corresponding entries in the iscsiPortalAttributesTable. A row in this table is created when the initiatorTypePortal bit is set in the iscsiPortalRoles attribute; it is destroyed when this bit is cleared. Each row in this table contains a portal group aggregation tag, indicating which portals an initiator may use together within a multiple-connection session. This table will be empty for iSCSI instances that contain only targets (such as most iSCSI devices). Many implementations use the same initiator tag for all nodes accessing targets via a given portal. These implementations will create a single row in iscsiIntrPortalAttributeTable, with an iscsiNodeIndex of zero. Other implementations do not use the same tag and/or port for all nodes; these implementations will create a row in this table for each (portal, node) tuple, using iscsiNodeIndex to designate the node for this portal tag and port. Bakke & Venkatesen Standards Track [Page 11] RFC 7147 iSCSI MIB April 2014 6.7. iscsiNode The iscsiNodeAttributesTable contains a list of iSCSI nodes, each of which may have an initiator role, a target role, or both. This table contains the node's attributes that are common to both roles, such as its iSCSI name and alias string. Attributes specific to initiators or targets are available in the iscsiTarget and iscsiInitiator objects. Each row in this table that can fulfill a target role has a corresponding row in the iscsiTarget table; each entry that fulfills an initiator role has a row in the iscsiInitiator table. Nodes such as copy managers that can take on both roles have a corresponding row in each table. This table also contains the login negotiations preferences for this node. These objects indicate the values this node will offer or prefer in the operational negotiation phase of the login process. For most implementations, each entry in the table also contains a RowPointer to the transport table entry in the SCSI MIB module that this iSCSI node represents. For implementations without a standard SCSI layer above iSCSI, such as an iSCSI proxy or gateway, this RowPointer can point to a row in an implementation-specific table that this iSCSI node represents. 6.8. iscsiTarget The iscsiTargetAttributesTable contains target-specific attributes for iSCSI nodes. Each entry in this table uses the same index values as its corresponding iscsiNode entry. This table contains attributes used to indicate the last failure that was (or should have been) sent as a notification. This table is augmented by the iscsiTargetLoginStatsTable and the iscsiTargetLogoutStatsTable, which count the numbers of normal and abnormal logins and logouts to this target. 6.9. iscsiTgtAuthorization The iscsiTgtAuthAttributesTable contains an entry for each initiator identifier that will be allowed to access the target under which it appears. Each entry contains a RowPointer to a user identity in the IPS Authorization MIB module, which contains the name, address, and credential information necessary to authenticate the initiator. Bakke & Venkatesen Standards Track [Page 12] RFC 7147 iSCSI MIB April 2014 6.10. iscsiInitiator The iscsiInitiatorAttributesTable contains a list of initiator- specific attributes for iSCSI nodes. Each entry in this table uses the same index values as its corresponding iscsiNode entry. Most implementations will include a single entry in this table, regardless of the number of physical interfaces the initiator may use. This table is augmented by the iscsiInitiatorLoginStatsTable and the iscsiInitiatorLogoutStatsTable, which count the numbers of normal and abnormal logins and logouts from this initiator. 6.11. iscsiIntrAuthorization The iscsiIntrAuthAttributesTable contains an entry for each target identifier to which the initiator is configured to establish a session. Each entry contains a RowPointer to a user identity in the IPS Authorization MIB module, which contains the name, address, and credential information necessary to identify (for discovery purposes) and authenticate the target. 6.12. iscsiSession The iscsiSessionAttributesTable contains a set of rows that list the sessions known to exist locally for each node in each iSCSI instance. The session type for each session indicates whether the session is used for normal SCSI commands or for discovery using the SendTargets text command. Discovery sessions that do not belong to any particular node have a node index attribute of zero. The session direction for each session indicates whether it is an Inbound session or an Outbound session. Inbound sessions are from some other initiator to the target node under which the session appears. Outbound sessions are from the initiator node under which the session appears to a target outside this iSCSI instance. Many attributes may be negotiated when starting an iSCSI session. Most of these attributes are included in the session object. Bakke & Venkatesen Standards Track [Page 13] RFC 7147 iSCSI MIB April 2014 Some attributes, such as the integrity and authentication schemes, have some standard values that can be extended by vendors to include their own schemes. These contain an object identifier, rather than the expected enumerated type, to allow these values to be extended by other MIB modules, such as an enterprise MIB module. The iscsiSessionStatsTable includes statistics related to performance; it counts iSCSI data bytes and PDUs. For implementations that support error recovery without terminating a session, the iscsiSessionCxnErrorStatsTable contains counters for the numbers of digest and connection errors that have occurred within the session. 6.13. iscsiConnection The iscsiConnectionAttributesTable contains a list of active connections within each session. It contains the IP addresses and TCP (or other protocol) ports of both the local and remote sides of the connection. These may be used to locate other connection-related information and statistics in the TCP MIB module [RFC4022]. The attributes table also contains a connection state. This state is not meant to directly map to the state tables included within the iSCSI specification; they are meant to be simplified, higher-level definitions of connection state that provide information more useful to a user or network manager. No statistics are kept for connections. 6.14. IP Addresses and TCP Port Numbers The IP addresses in this module are represented by two attributes, one of type InetAddressType, and the other of type InetAddress. These are taken from [RFC4001], which specifies how to support addresses that may be either IPv4 or IPv6. The TCP port numbers that appear in a few of the structures are described as simply port numbers, with a protocol attribute indicating whether they are TCP ports or something else. This will allow the module to be compatible with iSCSI over transports other than TCP in the future. Bakke & Venkatesen Standards Track [Page 14] RFC 7147 iSCSI MIB April 2014 6.15. Descriptors: Using OIDs in Place of Enumerated Types The iSCSI MIB module has a few attributes, namely, the digest method attributes, where an enumerated type would work well, except that an implementation may need to extend the attribute and add types of its own. To make this work, this MIB module defines a set of object identities within the iscsiDescriptors subtree. Each of these object identities is basically an enumerated type. Attributes that make use of these object identities have a value that is an Object Identifier (OID) instead of an enumerated type. These OIDs can indicate either the object identities defined in this module or object identities defined elsewhere, such as in an enterprise MIB module. Those implementations that add their own digest methods should also define a corresponding object identity for each of these methods within their own enterprise MIB module, and return its OID whenever one of these attributes is using that method. 6.16. Notifications Three notifications are provided. One is sent by an initiator detecting a critical login failure, another is sent by a target detecting a critical login failure, and the third is sent upon a session being terminated due to an abnormal connection or digest failure. Critical failures are defined as those that may expose security-related problems that may require immediate action, such as failures due to authentication, authorization, or negotiation problems. Attributes in the initiator, target, and instance objects provide the information necessary to send in the notification, such as the initiator or target name and IP address at the other end that may have caused the failure. To avoid sending an excessive number of notifications due to multiple errors counted, an SNMP agent implementing the iSCSI MIB module SHOULD NOT send more than three iSCSI notifications in any 10-second period. The 3-in-10 rule was chosen because one notification every three seconds was deemed often enough, but should two or three different notifications happen at the same time, it would not be desirable to suppress them. Three notifications in 10 seconds is a happy medium, where a short burst of notifications is allowed, without inundating the network and/or notification host with a large number of notifications. Bakke & Venkatesen Standards Track [Page 15] RFC 7147 iSCSI MIB April 2014 7. MIB Definition ISCSI-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, NOTIFICATION-TYPE, Unsigned32, Counter32, Counter64, Gauge32, mib-2 FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue, RowPointer, TimeStamp, RowStatus, AutonomousType, StorageType FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF SnmpAdminString FROM SNMP-FRAMEWORK-MIB -- RFC 3411 InetAddressType, InetAddress, InetPortNumber FROM INET-ADDRESS-MIB -- RFC 4001 ; iscsiMibModule MODULE-IDENTITY LAST-UPDATED "201402180000Z" -- February 18, 2014 ORGANIZATION "IETF STORage Maintenance (STORM) Working Group" CONTACT-INFO " Working Group Email: storm@ietf.org Attn: Mark Bakke Dell Email: mark_bakke@dell.com Prakash Venkatesen HCL Technologies Email: prakashvn@hcl.com" DESCRIPTION "This module defines management information specific to the iSCSI protocol. Copyright (c) 2014 IETF Trust and the persons identified as authors of the code. All rights reserved. Redistribution and use in source and binary forms, with or without modification, is permitted pursuant to, and subject to the license terms contained in, the Simplified BSD Bakke & Venkatesen Standards Track [Page 16] RFC 7147 iSCSI MIB April 2014 License set forth in Section 4.c of the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info)." REVISION "201402180000Z" DESCRIPTION "Second version of the iSCSI Protocol MIB Module. RFC 7143 makes several updates to [RFC3720]. This version makes corresponding updates to the MIB module. This MIB module published as RFC 7147." REVISION "200605220000Z" DESCRIPTION "Initial version of the iSCSI Protocol MIB module. This MIB module published as RFC 4544." ::= { mib-2 142 } iscsiNotifications OBJECT IDENTIFIER ::= { iscsiMibModule 0 } iscsiObjects OBJECT IDENTIFIER ::= { iscsiMibModule 1 } iscsiConformance OBJECT IDENTIFIER ::= { iscsiMibModule 2 } iscsiAdmin OBJECT IDENTIFIER ::= { iscsiMibModule 3 } -- Textual Conventions IscsiTransportProtocol ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "This data type is used to define the transport protocols that will carry iSCSI PDUs. Protocol numbers are assigned by IANA. A current list of all assignments is available from ." SYNTAX Unsigned32 (0..255) IscsiDigestMethod ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This data type represents the methods possible for digest negotiation. none - a placeholder for a secondary digest method that means only the primary method can be used. other - a digest method other than those defined below. noDigest - does not support digests (will operate without a digest (Note: implementations must support digests to be compliant with RFC 7143). CRC32c - require a CRC32C digest." Bakke & Venkatesen Standards Track [Page 17] RFC 7147 iSCSI MIB April 2014 REFERENCE "RFC 7143, Section 13.1, HeaderDigest and DataDigest" SYNTAX INTEGER { none(1), other(2), noDigest(3), crc32c(4) } IscsiName ::= TEXTUAL-CONVENTION DISPLAY-HINT "223t" STATUS current DESCRIPTION "This data type is used for objects whose value is an iSCSI name with the properties described in RFC 7143, Section 4.2.7.1, and encoded as specified in RFC 7143, Section 4.2.7.2. A zero-length string indicates the absence of an iSCSI name." REFERENCE "RFC 7143, Section 4.2.7, iSCSI Names." SYNTAX OCTET STRING (SIZE(0 | 16..223)) --********************************************************************** iscsiDescriptors OBJECT IDENTIFIER ::= { iscsiAdmin 1 } iscsiHeaderIntegrityTypes OBJECT IDENTIFIER ::= { iscsiDescriptors 1 } iscsiHdrIntegrityNone OBJECT-IDENTITY STATUS current DESCRIPTION "The authoritative identifier when no integrity scheme for the header is being used." REFERENCE "RFC 7143, Section 13.1, HeaderDigest and DataDigest" ::= { iscsiHeaderIntegrityTypes 1 } iscsiHdrIntegrityCrc32c OBJECT-IDENTITY STATUS current DESCRIPTION "The authoritative identifier when the integrity scheme for the header is CRC32c." REFERENCE "RFC 7143, Section 13.1, HeaderDigest and DataDigest" ::= { iscsiHeaderIntegrityTypes 2 } iscsiDataIntegrityTypes OBJECT IDENTIFIER ::= { iscsiDescriptors 2 } Bakke & Venkatesen Standards Track [Page 18] RFC 7147 iSCSI MIB April 2014 iscsiDataIntegrityNone OBJECT-IDENTITY STATUS current DESCRIPTION "The authoritative identifier when no integrity scheme for the data is being used." REFERENCE "RFC 7143, Section 13.1, HeaderDigest and DataDigest" ::= { iscsiDataIntegrityTypes 1 } iscsiDataIntegrityCrc32c OBJECT-IDENTITY STATUS current DESCRIPTION "The authoritative identifier when the integrity scheme for the data is CRC32c." REFERENCE "RFC 7143, Section 13.1, HeaderDigest and DataDigest" ::= { iscsiDataIntegrityTypes 2 } --********************************************************************** iscsiInstance OBJECT IDENTIFIER ::= { iscsiObjects 1 } -- Instance Attributes Table iscsiInstanceAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiInstanceAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of iSCSI instances present on the system." ::= { iscsiInstance 1 } iscsiInstanceAttributesEntry OBJECT-TYPE SYNTAX IscsiInstanceAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing management information applicable to a particular iSCSI instance." INDEX { iscsiInstIndex } ::= { iscsiInstanceAttributesTable 1 } IscsiInstanceAttributesEntry ::= SEQUENCE { iscsiInstIndex Unsigned32, iscsiInstDescr SnmpAdminString, iscsiInstVersionMin Unsigned32, iscsiInstVersionMax Unsigned32, iscsiInstVendorID SnmpAdminString, Bakke & Venkatesen Standards Track [Page 19] RFC 7147 iSCSI MIB April 2014 iscsiInstVendorVersion SnmpAdminString, iscsiInstPortalNumber Unsigned32, iscsiInstNodeNumber Unsigned32, iscsiInstSessionNumber Unsigned32, iscsiInstSsnFailures Counter32, iscsiInstLastSsnFailureType AutonomousType, iscsiInstLastSsnRmtNodeName IscsiName, iscsiInstDiscontinuityTime TimeStamp, iscsiInstXNodeArchitecture SnmpAdminString } iscsiInstIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer used to uniquely identify a particular iSCSI instance. This index value must not be modified or reused by an agent unless a reboot has occurred. An agent should attempt to keep this value persistent across reboots." ::= { iscsiInstanceAttributesEntry 1 } iscsiInstDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A UTF-8 string, determined by the implementation to describe the iSCSI instance. When only a single instance is present, this object may be set to the zero-length string; with multiple iSCSI instances, it may be used in an implementation-dependent manner to describe the purpose of the respective instance." ::= { iscsiInstanceAttributesEntry 2 } iscsiInstVersionMin OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum version number of the iSCSI specification such that this iSCSI instance supports this minimum value, the maximum value indicated by the corresponding instance in iscsiInstVersionMax, and all versions in between." REFERENCE "RFC 7143, Section 11.12, Login Request" Bakke & Venkatesen Standards Track [Page 20] RFC 7147 iSCSI MIB April 2014 ::= { iscsiInstanceAttributesEntry 3 } iscsiInstVersionMax OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum version number of the iSCSI specification such that this iSCSI instance supports this maximum value, the minimum value indicated by the corresponding instance in iscsiInstVersionMin, and all versions in between." REFERENCE "RFC 7143, Section 11.12, Login Request" ::= { iscsiInstanceAttributesEntry 4 } iscsiInstVendorID OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A UTF-8 string describing the manufacturer of the implementation of this instance." ::= { iscsiInstanceAttributesEntry 5 } iscsiInstVendorVersion OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A UTF-8 string set by the manufacturer describing the version of the implementation of this instance. The format of this string is determined solely by the manufacturer; the string is for informational purposes only. It is unrelated to the iSCSI specification version numbers." ::= { iscsiInstanceAttributesEntry 6 } iscsiInstPortalNumber OBJECT-TYPE SYNTAX Unsigned32 UNITS "transport endpoints" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of rows in the iscsiPortalAttributesTable that are currently associated with this iSCSI instance." ::= { iscsiInstanceAttributesEntry 7 } iscsiInstNodeNumber OBJECT-TYPE Bakke & Venkatesen Standards Track [Page 21] RFC 7147 iSCSI MIB April 2014 SYNTAX Unsigned32 UNITS "iSCSI nodes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of rows in the iscsiNodeAttributesTable that are currently associated with this iSCSI instance." ::= { iscsiInstanceAttributesEntry 8 } iscsiInstSessionNumber OBJECT-TYPE SYNTAX Unsigned32 UNITS "sessions" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of rows in the iscsiSessionAttributesTable that are currently associated with this iSCSI instance." ::= { iscsiInstanceAttributesEntry 9 } iscsiInstSsnFailures OBJECT-TYPE SYNTAX Counter32 UNITS "sessions" MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of times a session belonging to this instance has failed. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiInstDiscontinuityTime." REFERENCE "RFC 7143, Section 13.1, HeaderDigest and DataDigest" ::= { iscsiInstanceAttributesEntry 10 } iscsiInstLastSsnFailureType OBJECT-TYPE SYNTAX AutonomousType MAX-ACCESS read-only STATUS current DESCRIPTION "The counter object in the iscsiInstanceSsnErrorStatsTable that was incremented when the last session failure occurred. If the reason for failure is not found in the iscsiInstanceSsnErrorStatsTable, the value { 0.0 } is used instead." ::= { iscsiInstanceAttributesEntry 11 } iscsiInstLastSsnRmtNodeName OBJECT-TYPE SYNTAX IscsiName Bakke & Venkatesen Standards Track [Page 22] RFC 7147 iSCSI MIB April 2014 MAX-ACCESS read-only STATUS current DESCRIPTION "The iSCSI name of the remote node from the failed session." ::= { iscsiInstanceAttributesEntry 12 } iscsiInstDiscontinuityTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of SysUpTime on the most recent occasion at which any one or more of this instance's counters suffered a discontinuity. If no such discontinuities have occurred since the last re-initialization of the local management subsystem, then this object contains a zero value." ::= { iscsiInstanceAttributesEntry 13 } iscsiInstXNodeArchitecture OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A UTF-8 string set by the manufacturer declaring the details of its iSCSI node architecture to the remote endpoint. These details may include, but are not limited to, iSCSI vendor software, firmware, or hardware versions, the OS version, or hardware architecture. The format of this string is determined solely by the manufacturer; the string is for informational purposes only. It is unrelated to the iSCSI specification version numbers." REFERENCE "RFC 7143, Section 13.26, X#NodeArchitecture" ::= { iscsiInstanceAttributesEntry 14 } -- Instance Session Failure Stats Table iscsiInstanceSsnErrorStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiInstanceSsnErrorStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Statistics regarding the occurrences of error types that result in a session failure." ::= { iscsiInstance 2 } Bakke & Venkatesen Standards Track [Page 23] RFC 7147 iSCSI MIB April 2014 iscsiInstanceSsnErrorStatsEntry OBJECT-TYPE SYNTAX IscsiInstanceSsnErrorStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing management information applicable to a particular iSCSI instance." AUGMENTS { iscsiInstanceAttributesEntry } ::= { iscsiInstanceSsnErrorStatsTable 1 } IscsiInstanceSsnErrorStatsEntry ::= SEQUENCE { iscsiInstSsnDigestErrors Counter32, iscsiInstSsnCxnTimeoutErrors Counter32, iscsiInstSsnFormatErrors Counter32, iscsiInstSsnTgtUnmappedErrors Counter32 } iscsiInstSsnDigestErrors OBJECT-TYPE SYNTAX Counter32 UNITS "sessions" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of sessions that failed due to receipt of a PDU containing header or data digest errors. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiInstDiscontinuityTime." REFERENCE "RFC 7143, Section 7.8, Digest Errors" ::= { iscsiInstanceSsnErrorStatsEntry 1 } iscsiInstSsnCxnTimeoutErrors OBJECT-TYPE SYNTAX Counter32 UNITS "sessions" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of sessions that failed due to a sequence exceeding a time limit. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiInstDiscontinuityTime." REFERENCE "RFC 7143, Section 7.5, Connection Timeout Management" ::= { iscsiInstanceSsnErrorStatsEntry 2 } iscsiInstSsnFormatErrors OBJECT-TYPE SYNTAX Counter32 UNITS "sessions" Bakke & Venkatesen Standards Track [Page 24] RFC 7147 iSCSI MIB April 2014 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of sessions that failed due to receipt of a PDU that contained a format error. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiInstDiscontinuityTime." REFERENCE "RFC 7143 Section 7.7, Format Errors" ::= { iscsiInstanceSsnErrorStatsEntry 3 } iscsiInstSsnTgtUnmappedErrors OBJECT-TYPE SYNTAX Counter32 UNITS "sessions" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of sessions that failed due to the target becoming unmapped. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiInstDiscontinuityTime." ::= { iscsiInstanceSsnErrorStatsEntry 4 } --********************************************************************** iscsiPortal OBJECT IDENTIFIER ::= { iscsiObjects 2 } -- Portal Attributes Table iscsiPortalAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiPortalAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of transport endpoints (using TCP or another transport protocol) used by this iSCSI instance. An iSCSI instance may use a portal to listen for incoming connections to its targets, to initiate connections to other targets, or both." ::= { iscsiPortal 1 } iscsiPortalAttributesEntry OBJECT-TYPE SYNTAX IscsiPortalAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing management information applicable to a particular portal instance." INDEX { iscsiInstIndex, iscsiPortalIndex } ::= { iscsiPortalAttributesTable 1 } Bakke & Venkatesen Standards Track [Page 25] RFC 7147 iSCSI MIB April 2014 IscsiPortalAttributesEntry ::= SEQUENCE { iscsiPortalIndex Unsigned32, iscsiPortalRowStatus RowStatus, iscsiPortalRoles BITS, iscsiPortalAddrType InetAddressType, iscsiPortalAddr InetAddress, iscsiPortalProtocol IscsiTransportProtocol, iscsiPortalMaxRecvDataSegLength Unsigned32, iscsiPortalPrimaryHdrDigest IscsiDigestMethod, iscsiPortalPrimaryDataDigest IscsiDigestMethod, iscsiPortalSecondaryHdrDigest IscsiDigestMethod, iscsiPortalSecondaryDataDigest IscsiDigestMethod, iscsiPortalRecvMarker TruthValue, iscsiPortalStorageType StorageType, iscsiPortalDescr SnmpAdminString } iscsiPortalIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer used to uniquely identify a particular transport endpoint within this iSCSI instance. This index value must not be modified or reused by an agent unless a reboot has occurred. An agent should attempt to keep this value persistent across reboots." ::= { iscsiPortalAttributesEntry 1 } iscsiPortalRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This field allows entries to be dynamically added and removed from this table via SNMP. When adding a row to this table, all non-Index/RowStatus objects must be set. When the value of this object is 'active', the values of the other objects in this table cannot be changed. Rows may be discarded using RowStatus. Note that creating a row in this table will typically cause the agent to create one or more rows in the iscsiTgtPortalAttributesTable and/or the iscsiIntrPortalAttributesTable." ::= { iscsiPortalAttributesEntry 2 } iscsiPortalRoles OBJECT-TYPE Bakke & Venkatesen Standards Track [Page 26] RFC 7147 iSCSI MIB April 2014 SYNTAX BITS { targetTypePortal(0), initiatorTypePortal(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "A portal can operate in one or both of two roles: as a target portal and/or an initiator portal. If the portal will operate in both roles, both bits must be set. This object will define a corresponding row that will exist or must be created in the iscsiTgtPortalAttributesTable, the iscsiIntrPortalAttributesTable, or both. If the targetTypePortal bit is set, one or more corresponding iscsiTgtPortalAttributesEntry rows will be found or created. If the initiatorTypePortal bit is set, one or more corresponding iscsiIntrPortalAttributesEntry rows will be found or created. If both bits are set, one or more corresponding rows will be found or created in one of the above tables." ::= { iscsiPortalAttributesEntry 3 } iscsiPortalAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "The type of Internet Network Address contained in the corresponding instance of the iscsiPortalAddr." DEFVAL { ipv4 } ::= { iscsiPortalAttributesEntry 4 } iscsiPortalAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The portal's Internet Network Address, of the type specified by the object iscsiPortalAddrType. If iscsiPortalAddrType has the value 'dns', this address gets resolved to an IP address whenever a new iSCSI connection is established using this portal." ::= { iscsiPortalAttributesEntry 5 } iscsiPortalProtocol OBJECT-TYPE Bakke & Venkatesen Standards Track [Page 27] RFC 7147 iSCSI MIB April 2014 SYNTAX IscsiTransportProtocol MAX-ACCESS read-create STATUS current DESCRIPTION "The portal's transport protocol." DEFVAL { 6 } -- TCP ::= { iscsiPortalAttributesEntry 6 } iscsiPortalMaxRecvDataSegLength OBJECT-TYPE SYNTAX Unsigned32 (512..16777215) UNITS "bytes" MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum PDU length this portal can receive. This may be constrained by hardware characteristics, and individual implementations may choose not to allow this object to be changed." REFERENCE "RFC 7143, Section 13.12, MaxRecvDataSegmentLength" DEFVAL { 8192 } ::= { iscsiPortalAttributesEntry 7 } iscsiPortalPrimaryHdrDigest OBJECT-TYPE SYNTAX IscsiDigestMethod MAX-ACCESS read-create STATUS current DESCRIPTION "The preferred header digest for this portal." DEFVAL { crc32c } ::= { iscsiPortalAttributesEntry 8 } iscsiPortalPrimaryDataDigest OBJECT-TYPE SYNTAX IscsiDigestMethod MAX-ACCESS read-create STATUS current DESCRIPTION "The preferred data digest method for this portal." DEFVAL { crc32c } ::= { iscsiPortalAttributesEntry 9 } iscsiPortalSecondaryHdrDigest OBJECT-TYPE SYNTAX IscsiDigestMethod MAX-ACCESS read-create STATUS current DESCRIPTION "An alternate header digest preference for this portal." DEFVAL { noDigest } Bakke & Venkatesen Standards Track [Page 28] RFC 7147 iSCSI MIB April 2014 ::= { iscsiPortalAttributesEntry 10 } iscsiPortalSecondaryDataDigest OBJECT-TYPE SYNTAX IscsiDigestMethod MAX-ACCESS read-create STATUS current DESCRIPTION "An alternate data digest preference for this portal." DEFVAL { noDigest } ::= { iscsiPortalAttributesEntry 11 } iscsiPortalRecvMarker OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS deprecated DESCRIPTION "This object indicates whether or not this portal will request markers in its incoming data stream." REFERENCE "RFC 7143, Section 13.25, Obsoleted Keys." DEFVAL { false } ::= { iscsiPortalAttributesEntry 12 } iscsiPortalStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this row. Rows in this table that were created through an external process (e.g., not created via this MIB) may have a storage type of readOnly or permanent. Conceptual rows having the value 'permanent' need not allow write access to any columnar objects in the row." DEFVAL { nonVolatile } ::= { iscsiPortalAttributesEntry 13 } iscsiPortalDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A UTF-8 string, determined by the implementation to describe the iSCSI portal. When only a single instance is present, this object may be set to the zero-length string; with multiple iSCSI portals, it may be used in an implementation-dependent manner to describe the respective portal, and could include information such as Bakke & Venkatesen Standards Track [Page 29] RFC 7147 iSCSI MIB April 2014 Host Bus Adapter (HBA) model, description, and version, or software driver and version." ::= { iscsiPortalAttributesEntry 14 } --********************************************************************** iscsiTargetPortal OBJECT IDENTIFIER ::= { iscsiObjects 3 } -- Target Portal Attributes Table iscsiTgtPortalAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiTgtPortalAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of transport endpoints (using TCP or another transport protocol) on which this iSCSI instance listens for incoming connections to its targets." ::= { iscsiTargetPortal 1 } iscsiTgtPortalAttributesEntry OBJECT-TYPE SYNTAX IscsiTgtPortalAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing management information applicable to a particular portal instance that is used to listen for incoming connections to local targets. One or more rows in this table is populated by the agent for each iscsiPortalAttributesEntry row that has the bit targetTypePortal set in its iscsiPortalRoles column." INDEX { iscsiInstIndex, iscsiPortalIndex, iscsiTgtPortalNodeIndexOrZero } ::= { iscsiTgtPortalAttributesTable 1 } IscsiTgtPortalAttributesEntry ::= SEQUENCE { iscsiTgtPortalNodeIndexOrZero Unsigned32, iscsiTgtPortalPort InetPortNumber, iscsiTgtPortalTag Unsigned32 } iscsiTgtPortalNodeIndexOrZero OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer used to uniquely identify a particular node within an iSCSI instance present on the local system. Bakke & Venkatesen Standards Track [Page 30] RFC 7147 iSCSI MIB April 2014 For implementations where each {portal, node} tuple can have a different portal tag, this value will map to the iscsiNodeIndex. For implementations where the portal tag is the same for a given portal regardless of which node is using the portal, the value 0 (zero) is used." ::= { iscsiTgtPortalAttributesEntry 1 } iscsiTgtPortalPort OBJECT-TYPE SYNTAX InetPortNumber (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The portal's transport protocol port number on which the portal listens for incoming iSCSI connections when the portal is used as a target portal. This object's storage type is specified in iscsiPortalStorageType." ::= { iscsiTgtPortalAttributesEntry 2 } iscsiTgtPortalTag OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The portal's aggregation tag when the portal is used as a target portal. Multiple-connection sessions may be aggregated over portals sharing an identical aggregation tag. This object's storage type is specified in iscsiPortalStorageType." REFERENCE "RFC 7143, Section 4.4.1, iSCSI Architecture Model" ::= { iscsiTgtPortalAttributesEntry 3 } --********************************************************************** iscsiInitiatorPortal OBJECT IDENTIFIER ::= { iscsiObjects 4 } -- Initiator Portal Attributes Table iscsiIntrPortalAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiIntrPortalAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Internet Network Addresses (using TCP or another transport protocol) from which this iSCSI instance may initiate connections to other targets." Bakke & Venkatesen Standards Track [Page 31] RFC 7147 iSCSI MIB April 2014 ::= { iscsiInitiatorPortal 1 } iscsiIntrPortalAttributesEntry OBJECT-TYPE SYNTAX IscsiIntrPortalAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing management information applicable to a particular portal instance that is used to initiate connections to iSCSI targets. One or more rows in this table is populated by the agent for each iscsiPortalAttributesEntry row that has the bit initiatorTypePortal set in its iscsiPortalRoles column." INDEX { iscsiInstIndex, iscsiPortalIndex, iscsiIntrPortalNodeIndexOrZero } ::= { iscsiIntrPortalAttributesTable 1 } IscsiIntrPortalAttributesEntry ::= SEQUENCE { iscsiIntrPortalNodeIndexOrZero Unsigned32, iscsiIntrPortalTag Unsigned32 } iscsiIntrPortalNodeIndexOrZero OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer used to uniquely identify a particular node within an iSCSI instance present on the local system. For implementations where each {portal, node} tuple can have a different portal tag, this value will map to the iscsiNodeIndex. For implementations where the portal tag is the same for a given portal regardless of which node is using the portal, the value 0 (zero) is used." ::= { iscsiIntrPortalAttributesEntry 1 } iscsiIntrPortalTag OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The portal's aggregation tag when the portal is used as an initiator portal. Multiple-connection sessions may be aggregated over portals sharing an identical Bakke & Venkatesen Standards Track [Page 32] RFC 7147 iSCSI MIB April 2014 aggregation tag. This object's storage type is specified in iscsiPortalStorageType." REFERENCE "RFC 7143, Section 4.4.1, iSCSI Architecture Model" ::= { iscsiIntrPortalAttributesEntry 2 } --********************************************************************** iscsiNode OBJECT IDENTIFIER ::= { iscsiObjects 5 } -- Node Attributes Table iscsiNodeAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiNodeAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of iSCSI nodes belonging to each iSCSI instance present on the local system. An iSCSI node can act as an initiator, a target, or both." ::= { iscsiNode 1 } iscsiNodeAttributesEntry OBJECT-TYPE SYNTAX IscsiNodeAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A conceptual row containing management information applicable to a particular iSCSI node." INDEX { iscsiInstIndex, iscsiNodeIndex } ::= { iscsiNodeAttributesTable 1 } IscsiNodeAttributesEntry ::= SEQUENCE { iscsiNodeIndex Unsigned32, iscsiNodeName IscsiName, iscsiNodeAlias SnmpAdminString, iscsiNodeRoles BITS, iscsiNodeTransportType RowPointer, iscsiNodeInitialR2T TruthValue, iscsiNodeImmediateData TruthValue, iscsiNodeMaxOutstandingR2T Unsigned32, iscsiNodeFirstBurstLength Unsigned32, iscsiNodeMaxBurstLength Unsigned32, iscsiNodeMaxConnections Unsigned32, iscsiNodeDataSequenceInOrder TruthValue, iscsiNodeDataPDUInOrder TruthValue, iscsiNodeDefaultTime2Wait Unsigned32, iscsiNodeDefaultTime2Retain Unsigned32, Bakke & Venkatesen Standards Track [Page 33] RFC 7147 iSCSI MIB April 2014 iscsiNodeErrorRecoveryLevel Unsigned32, iscsiNodeDiscontinuityTime TimeStamp, iscsiNodeStorageType StorageType } iscsiNodeIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer used to uniquely identify a particular node within an iSCSI instance. This index value must not be modified or reused by an agent unless a reboot has occurred. An agent should attempt to keep this value persistent across reboots." ::= { iscsiNodeAttributesEntry 1 } iscsiNodeName OBJECT-TYPE SYNTAX IscsiName MAX-ACCESS read-only STATUS current DESCRIPTION "This node's iSCSI name, which is independent of the location of the node, and can be resolved into a set of addresses through various discovery services." ::= { iscsiNodeAttributesEntry 2 } iscsiNodeAlias OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A character string that is a human-readable name or description of the iSCSI node. If configured, this alias may be communicated to the initiator or target node at the remote end of the connection during a Login Request or Response message. This string is not used as an identifier, but it can be displayed by the system's user interface in a list of initiators and/or targets to which it is connected. If no alias exists, the value is a zero-length string." REFERENCE "RFC 7143, Sections 13.6 (TargetAlias) and 13.7 (InitiatorAlias)" ::= { iscsiNodeAttributesEntry 3 } iscsiNodeRoles OBJECT-TYPE Bakke & Venkatesen Standards Track [Page 34] RFC 7147 iSCSI MIB April 2014 SYNTAX BITS { targetTypeNode(0), initiatorTypeNode(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A node can operate in one or both of two roles: a target role and/or an initiator role. If the node will operate in both roles, both bits must be set. This object will also define the corresponding rows that will exist in the iscsiTargetAttributesTable, the iscsiInitiatorAttributesTable, or both. If the targetTypeNode bit is set, there will be a corresponding iscsiTargetAttributesEntry. If the initiatorTypeNode bit is set, there will be a corresponding iscsiInitiatorAttributesEntry. If both bits are set, there will be a corresponding iscsiTgtPortalAttributesEntry and iscsiPortalAttributesEntry." ::= { iscsiNodeAttributesEntry 4 } iscsiNodeTransportType OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "A pointer to the corresponding row in the appropriate table for this SCSI transport, thereby allowing management stations to locate the SCSI-level device that is represented by this iscsiNode. For example, it will usually point to the corresponding scsiTrnspt object in the SCSI MIB module. If no corresponding row exists, the value 0.0 must be used to indicate this." REFERENCE "SCSI-MIB, RFC 4455, Section 9, Object Definitions, scsiTransportTypes" ::= { iscsiNodeAttributesEntry 5 } iscsiNodeInitialR2T OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the InitialR2T preference for this node: true = YES, false = will try to negotiate NO, will accept YES " Bakke & Venkatesen Standards Track [Page 35] RFC 7147 iSCSI MIB April 2014 REFERENCE "RFC 7143, Section 13.10, InitialR2T" ::= { iscsiNodeAttributesEntry 6 } iscsiNodeImmediateData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates ImmediateData preference for this node: true = YES (but will accept NO), false = NO " REFERENCE "RFC 7143, Section 13.11, ImmediateData" DEFVAL { true } ::= { iscsiNodeAttributesEntry 7 } iscsiNodeMaxOutstandingR2T OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "R2Ts" MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum number of outstanding requests-to-transmit (R2Ts) allowed per iSCSI task." REFERENCE "RFC 7143, Section 13.17, MaxOutstandingR2T" DEFVAL { 1 } ::= { iscsiNodeAttributesEntry 8 } iscsiNodeFirstBurstLength OBJECT-TYPE SYNTAX Unsigned32 (512..16777215) UNITS "bytes" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum length (bytes) supported for unsolicited data to/from this node." REFERENCE "RFC 7143, Section 13.14, FirstBurstLength" DEFVAL { 65536 } ::= { iscsiNodeAttributesEntry 9 } iscsiNodeMaxBurstLength OBJECT-TYPE SYNTAX Unsigned32 (512..16777215) UNITS "bytes" MAX-ACCESS read-write Bakke & Venkatesen Standards Track [Page 36] RFC 7147 iSCSI MIB April 2014 STATUS current DESCRIPTION "The maximum number of bytes that can be sent within a single sequence of Data-In or Data-Out PDUs." REFERENCE "RFC 7143, Section 13.13, MaxBurstLength" DEFVAL { 262144 } ::= { iscsiNodeAttributesEntry 10 } iscsiNodeMaxConnections OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "connections" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of connections allowed in each session to and/or from this node." REFERENCE "RFC 7143, Section 13.2, MaxConnections" DEFVAL { 1 } ::= { iscsiNodeAttributesEntry 11 } iscsiNodeDataSequenceInOrder OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The DataSequenceInOrder preference of this node. False (=No) indicates that iSCSI data PDU sequences may be transferred in any order. True (=Yes) indicates that data PDU sequences must be transferred using continuously increasing offsets, except during error recovery." REFERENCE "RFC 7143, Section 13.19, DataSequenceInOrder" DEFVAL { true } ::= { iscsiNodeAttributesEntry 12 } iscsiNodeDataPDUInOrder OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The DataPDUInOrder preference of this node. False (=No) indicates that iSCSI data PDUs within sequences may be in any order. True (=Yes) indicates that data PDUs within sequences must be at continuously increasing addresses, with no gaps or overlay between PDUs." Bakke & Venkatesen Standards Track [Page 37] RFC 7147 iSCSI MIB April 2014 REFERENCE "RFC 7143, Section 13.18, DataPDUInOrder" DEFVAL { true } ::= { iscsiNodeAttributesEntry 13 } iscsiNodeDefaultTime2Wait OBJECT-TYPE SYNTAX Unsigned32 (0..3600) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The DefaultTime2Wait preference of this node. This is the minimum time, in seconds, to wait before attempting an explicit/implicit logout or active iSCSI task reassignment after an unexpected connection termination or a connection reset." REFERENCE "RFC 7143, Section 13.15, DefaultTime2Wait" DEFVAL { 2 } ::= { iscsiNodeAttributesEntry 14 } iscsiNodeDefaultTime2Retain OBJECT-TYPE SYNTAX Unsigned32 (0..3600) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The DefaultTime2Retain preference of this node. This is the maximum time, in seconds after an initial wait (Time2Wait), before which an active iSCSI task reassignment is still possible after an unexpected connection termination or a connection reset." REFERENCE "RFC 7143, Section 13.16, DefaultTime2Retain" DEFVAL { 20 } ::= { iscsiNodeAttributesEntry 15 } iscsiNodeErrorRecoveryLevel OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The ErrorRecoveryLevel preference of this node. Currently, only 0-2 are valid. This object is designed to accommodate future error-recovery levels. Bakke & Venkatesen Standards Track [Page 38] RFC 7147 iSCSI MIB April 2014 Higher error-recovery levels imply support in addition to support for the lower error level functions. In other words, error level 2 implies support for levels 0-1, since those functions are subsets of error level 2." REFERENCE "RFC 7143, Section 13.20, ErrorRecoveryLevel" DEFVAL { 0 } ::= { iscsiNodeAttributesEntry 16 } iscsiNodeDiscontinuityTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of SysUpTime on the most recent occasion at which any one or more of this node's counters suffered a discontinuity. If no such discontinuities have occurred since the last re-initialization of the local management subsystem, then this object contains a zero value." ::= { iscsiNodeAttributesEntry 17 } iscsiNodeStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-write STATUS current DESCRIPTION "The storage type for all read-write objects within this row. Rows in this table are always created via an external process (e.g., not created via this MIB module). Conceptual rows having the value 'permanent' need not allow Write access to any columnar objects in the row. If this object has the value 'volatile', modifications to read-write objects in this row are not persistent across reboots. If this object has the value 'nonVolatile', modifications to objects in this row are persistent. An implementation may choose to allow this object to be set to either 'nonVolatile' or 'volatile', allowing the management application to choose this behavior." DEFVAL { volatile } ::= { iscsiNodeAttributesEntry 18 } --********************************************************************** Bakke & Venkatesen Standards Track [Page 39] RFC 7147 iSCSI MIB April 2014 iscsiTarget OBJECT IDENTIFIER ::= { iscsiObjects 6 } -- Target Attributes Table iscsiTargetAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiTargetAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of iSCSI nodes that can take on a target role, belonging to each iSCSI instance present on the local system." ::= { iscsiTarget 1 } iscsiTargetAttributesEntry OBJECT-TYPE SYNTAX IscsiTargetAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing management information applicable to a particular node that can take on a target role." INDEX { iscsiInstIndex, iscsiNodeIndex } ::= { iscsiTargetAttributesTable 1 } IscsiTargetAttributesEntry ::= SEQUENCE { iscsiTgtLoginFailures Counter32, iscsiTgtLastFailureTime TimeStamp, iscsiTgtLastFailureType AutonomousType, iscsiTgtLastIntrFailureName IscsiName, iscsiTgtLastIntrFailureAddrType InetAddressType, iscsiTgtLastIntrFailureAddr InetAddress, iscsiTgtLastIntrFailurePort InetPortNumber } iscsiTgtLoginFailures OBJECT-TYPE SYNTAX Counter32 UNITS "failed login attempts" MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of times a login attempt to this local target has failed. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiTargetAttributesEntry 1 } Bakke & Venkatesen Standards Track [Page 40] RFC 7147 iSCSI MIB April 2014 iscsiTgtLastFailureTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The timestamp of the most recent failure of a login attempt to this target. A value of zero indicates that no such failures have occurred since the last system boot." ::= { iscsiTargetAttributesEntry 2 } iscsiTgtLastFailureType OBJECT-TYPE SYNTAX AutonomousType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the most recent failure of a login attempt to this target, represented as the OID of the counter object in iscsiTargetLoginStatsTable for which the relevant instance was incremented. If no such failures have occurred since the last system boot, this attribute will have the value 0.0. A value of 0.0 may also be used to indicate a type that is not represented by any of the counters in iscsiTargetLoginStatsTable." ::= { iscsiTargetAttributesEntry 3 } iscsiTgtLastIntrFailureName OBJECT-TYPE SYNTAX IscsiName MAX-ACCESS read-only STATUS current DESCRIPTION "The iSCSI name of the initiator that failed the last login attempt. If no such failures have occurred since the last system boot, this value is a zero-length string." ::= { iscsiTargetAttributesEntry 4 } iscsiTgtLastIntrFailureAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet Network Address contained in the corresponding instance of the iscsiTgtLastIntrFailureAddr. The value 'dns' is not allowed. If no such failures have occurred since the last system boot, this value is zero." ::= { iscsiTargetAttributesEntry 5 } iscsiTgtLastIntrFailureAddr OBJECT-TYPE SYNTAX InetAddress Bakke & Venkatesen Standards Track [Page 41] RFC 7147 iSCSI MIB April 2014 MAX-ACCESS read-only STATUS current DESCRIPTION "An Internet Network Address, of the type specified by the object iscsiTgtLastIntrFailureAddrType, giving the host address of the initiator that failed the last login attempt. If no such failures have occurred since the last system boot, this value is a zero-length string." ::= { iscsiTargetAttributesEntry 6 } iscsiTgtLastIntrFailurePort OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The transport protocol port number used by the initiator that failed the last login attempt. If no such failures have occurred since the last system boot, this value is a zero-length string." ::= { iscsiTargetAttributesEntry 7 } -- Target Login Stats Table iscsiTargetLoginStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiTargetLoginStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of counters that keep a record of the results of initiators' login attempts to this target." ::= { iscsiTarget 2 } iscsiTargetLoginStatsEntry OBJECT-TYPE SYNTAX IscsiTargetLoginStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing counters for each result of a login attempt to this target." AUGMENTS { iscsiTargetAttributesEntry } ::= { iscsiTargetLoginStatsTable 1 } IscsiTargetLoginStatsEntry ::= SEQUENCE { iscsiTgtLoginAccepts Counter32, iscsiTgtLoginOtherFails Counter32, iscsiTgtLoginRedirects Counter32, iscsiTgtLoginAuthorizeFails Counter32, iscsiTgtLoginAuthenticateFails Counter32, Bakke & Venkatesen Standards Track [Page 42] RFC 7147 iSCSI MIB April 2014 iscsiTgtLoginNegotiateFails Counter32 } iscsiTgtLoginAccepts OBJECT-TYPE SYNTAX Counter32 UNITS "successful logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Login Response PDUs with status 0x0000, Accept Login, transmitted by this target. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiTargetLoginStatsEntry 1 } iscsiTgtLoginOtherFails OBJECT-TYPE SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Login Response PDUs that were transmitted by this target and that were not counted by any other object in the row. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiTargetLoginStatsEntry 2 } iscsiTgtLoginRedirects OBJECT-TYPE SYNTAX Counter32 UNITS "redirected logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Login Response PDUs with status class 0x01, Redirection, transmitted by this target. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiTargetLoginStatsEntry 3 } iscsiTgtLoginAuthorizeFails OBJECT-TYPE Bakke & Venkatesen Standards Track [Page 43] RFC 7147 iSCSI MIB April 2014 SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Login Response PDUs with status 0x0202, Forbidden Target, transmitted by this target. If this counter is incremented, an iscsiTgtLoginFailure notification should be generated. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiTargetLoginStatsEntry 4 } iscsiTgtLoginAuthenticateFails OBJECT-TYPE SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Login Response PDUs with status 0x0201, Authentication Failed, transmitted by this target. If this counter is incremented, an iscsiTgtLoginFailure notification should be generated. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiTargetLoginStatsEntry 5 } iscsiTgtLoginNegotiateFails OBJECT-TYPE SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times a target has effectively refused a login because the parameter negotiation failed. If this counter is incremented, an iscsiTgtLoginFailure notification should be generated. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." ::= { iscsiTargetLoginStatsEntry 6 } Bakke & Venkatesen Standards Track [Page 44] RFC 7147 iSCSI MIB April 2014 -- Target Logout Stats Table iscsiTargetLogoutStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiTargetLogoutStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "When a target receives a Logout command, it responds with a Logout Response that carries a status code. This table contains counters for both normal and abnormal Logout Requests received by this target." ::= { iscsiTarget 3 } iscsiTargetLogoutStatsEntry OBJECT-TYPE SYNTAX IscsiTargetLogoutStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing counters of Logout Response PDUs that were received by this target." AUGMENTS { iscsiTargetAttributesEntry } ::= { iscsiTargetLogoutStatsTable 1 } IscsiTargetLogoutStatsEntry ::= SEQUENCE { iscsiTgtLogoutNormals Counter32, iscsiTgtLogoutOthers Counter32, iscsiTgtLogoutCxnClosed Counter32, iscsiTgtLogoutCxnRemoved Counter32 } iscsiTgtLogoutNormals OBJECT-TYPE SYNTAX Counter32 UNITS "normal logouts" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Logout Command PDUs received by this target, with reason code 0 (closes the session). If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.14.1, Reason Code" ::= { iscsiTargetLogoutStatsEntry 1 } iscsiTgtLogoutOthers OBJECT-TYPE SYNTAX Counter32 UNITS "abnormal logouts" MAX-ACCESS read-only Bakke & Venkatesen Standards Track [Page 45] RFC 7147 iSCSI MIB April 2014 STATUS current DESCRIPTION "The count of Logout Command PDUs received by this target, with any reason code other than 0. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.14.1, Reason Code" ::= { iscsiTargetLogoutStatsEntry 2 } iscsiTgtLogoutCxnClosed OBJECT-TYPE SYNTAX Counter32 UNITS "abnormal logouts" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Logout Command PDUs received by this target, with reason code 1 (closes the connection). If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.14.1, Reason Code" ::= { iscsiTargetLogoutStatsEntry 3 } iscsiTgtLogoutCxnRemoved OBJECT-TYPE SYNTAX Counter32 UNITS "abnormal logouts" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Logout Command PDUs received by this target, with reason code 2 (removes the connection). If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.14.1, Reason Code" ::= { iscsiTargetLogoutStatsEntry 4 } --********************************************************************** iscsiTgtAuthorization OBJECT IDENTIFIER ::= { iscsiObjects 7 } -- Target Authorization Attributes Table iscsiTgtAuthAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiTgtAuthAttributesEntry MAX-ACCESS not-accessible STATUS current Bakke & Venkatesen Standards Track [Page 46] RFC 7147 iSCSI MIB April 2014 DESCRIPTION "A list of initiator identities that are authorized to access each target node within each iSCSI instance present on the local system." ::= { iscsiTgtAuthorization 1 } iscsiTgtAuthAttributesEntry OBJECT-TYPE SYNTAX IscsiTgtAuthAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing management information applicable to a particular target node's authorized initiator identity." INDEX { iscsiInstIndex, iscsiNodeIndex, iscsiTgtAuthIndex } ::= { iscsiTgtAuthAttributesTable 1 } IscsiTgtAuthAttributesEntry ::= SEQUENCE { iscsiTgtAuthIndex Unsigned32, iscsiTgtAuthRowStatus RowStatus, iscsiTgtAuthIdentity RowPointer, iscsiTgtAuthStorageType StorageType } iscsiTgtAuthIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer used to uniquely identify a particular target's authorized initiator identity within an iSCSI instance present on the local system. This index value must not be modified or reused by an agent unless a reboot has occurred. An agent should attempt to keep this value persistent across reboots." ::= { iscsiTgtAuthAttributesEntry 1 } iscsiTgtAuthRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This field allows entries to be dynamically added and removed from this table via SNMP. When adding a row to this table, all non-Index/RowStatus objects must be set. When the value of this object is 'active', the values of the other objects in this table cannot be changed. Rows may be discarded using RowStatus." Bakke & Venkatesen Standards Track [Page 47] RFC 7147 iSCSI MIB April 2014 ::= { iscsiTgtAuthAttributesEntry 2 } iscsiTgtAuthIdentity OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-create STATUS current DESCRIPTION "A pointer to the corresponding user entry in the IPS-AUTH MIB module that will be allowed to access this iSCSI target." REFERENCE "IPS-AUTH MIB, RFC 4545, Section 7.3, ipsAuthIdentity" ::= { iscsiTgtAuthAttributesEntry 3 } iscsiTgtAuthStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this row. Rows in this table that were created through an external process (e.g., not created via this MIB) may have a storage type of readOnly or permanent. Conceptual rows having the value 'permanent' need not allow write access to any columnar objects in the row." DEFVAL { nonVolatile } ::= { iscsiTgtAuthAttributesEntry 4 } --********************************************************************** iscsiInitiator OBJECT IDENTIFIER ::= { iscsiObjects 8 } -- Initiator Attributes Table iscsiInitiatorAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiInitiatorAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of iSCSI nodes that can take on an initiator role, belonging to each iSCSI instance present on the local system." ::= { iscsiInitiator 1 } iscsiInitiatorAttributesEntry OBJECT-TYPE SYNTAX IscsiInitiatorAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION Bakke & Venkatesen Standards Track [Page 48] RFC 7147 iSCSI MIB April 2014 "An entry (row) containing management information applicable to a particular iSCSI node that has initiator capabilities." INDEX { iscsiInstIndex, iscsiNodeIndex } ::= { iscsiInitiatorAttributesTable 1 } IscsiInitiatorAttributesEntry ::= SEQUENCE { iscsiIntrLoginFailures Counter32, iscsiIntrLastFailureTime TimeStamp, iscsiIntrLastFailureType AutonomousType, iscsiIntrLastTgtFailureName IscsiName, iscsiIntrLastTgtFailureAddrType InetAddressType, iscsiIntrLastTgtFailureAddr InetAddress, iscsiIntrLastTgtFailurePort InetPortNumber } iscsiIntrLoginFailures OBJECT-TYPE SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of times a login attempt from this local initiator has failed. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiInitiatorAttributesEntry 1 } iscsiIntrLastFailureTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The timestamp of the most recent failure of a login attempt from this initiator. A value of zero indicates that no such failures have occurred since the last system boot." ::= { iscsiInitiatorAttributesEntry 2 } iscsiIntrLastFailureType OBJECT-TYPE SYNTAX AutonomousType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the most recent failure of a login attempt from this initiator, represented as the OID of the counter object in iscsiInitiatorLoginStatsTable for which the Bakke & Venkatesen Standards Track [Page 49] RFC 7147 iSCSI MIB April 2014 relevant instance was incremented. If no such failures have occurred since the last system boot, this attribute will have the value 0.0. A value of 0.0 may also be used to indicate a type that is not represented by any of the counters in iscsiInitiatorLoginStatsTable." ::= { iscsiInitiatorAttributesEntry 3 } iscsiIntrLastTgtFailureName OBJECT-TYPE SYNTAX IscsiName MAX-ACCESS read-only STATUS current DESCRIPTION "A UTF-8 string giving the name of the target that failed the last login attempt. If no such failures have occurred since the last system boot, this value is a zero-length string." ::= { iscsiInitiatorAttributesEntry 4 } iscsiIntrLastTgtFailureAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet Network Address contained in the corresponding instance of the iscsiIntrLastTgtFailureAddr. The value 'dns' is not allowed. If no such failures have occurred since the last system boot, this value is zero." ::= { iscsiInitiatorAttributesEntry 5 } iscsiIntrLastTgtFailureAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "An Internet Network Address, of the type specified by the object iscsiIntrLastTgtFailureAddrType, giving the host address of the target that failed the last login attempt. If no such failures have occurred since the last system boot, this value is a zero-length string." ::= { iscsiInitiatorAttributesEntry 6 } iscsiIntrLastTgtFailurePort OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The transport protocol port number used by the target that failed the last login attempt. If no such failures have occurred since the last system boot, Bakke & Venkatesen Standards Track [Page 50] RFC 7147 iSCSI MIB April 2014 this value is a zero-length string." ::= { iscsiInitiatorAttributesEntry 7 } -- Initiator Login Stats Table iscsiInitiatorLoginStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiInitiatorLoginStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of counters that keep track of the results of this initiator's login attempts." ::= { iscsiInitiator 2 } iscsiInitiatorLoginStatsEntry OBJECT-TYPE SYNTAX IscsiInitiatorLoginStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing counters of each result of this initiator's login attempts." AUGMENTS { iscsiInitiatorAttributesEntry } ::= { iscsiInitiatorLoginStatsTable 1 } IscsiInitiatorLoginStatsEntry ::= SEQUENCE { iscsiIntrLoginAcceptRsps Counter32, iscsiIntrLoginOtherFailRsps Counter32, iscsiIntrLoginRedirectRsps Counter32, iscsiIntrLoginAuthFailRsps Counter32, iscsiIntrLoginAuthenticateFails Counter32, iscsiIntrLoginNegotiateFails Counter32, iscsiIntrLoginAuthorizeFails Counter32 } iscsiIntrLoginAcceptRsps OBJECT-TYPE SYNTAX Counter32 UNITS "successful logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Login Response PDUs with status 0x0000, Accept Login, received by this initiator. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiInitiatorLoginStatsEntry 1 } Bakke & Venkatesen Standards Track [Page 51] RFC 7147 iSCSI MIB April 2014 iscsiIntrLoginOtherFailRsps OBJECT-TYPE SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Login Response PDUs received by this initiator with any status code not counted in the objects below. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiInitiatorLoginStatsEntry 2 } iscsiIntrLoginRedirectRsps OBJECT-TYPE SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Login Response PDUs with status class 0x01, Redirection, received by this initiator. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiInitiatorLoginStatsEntry 3 } iscsiIntrLoginAuthFailRsps OBJECT-TYPE SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Login Response PDUs with status class 0x201, Authentication Failed, received by this initiator. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiInitiatorLoginStatsEntry 4 } iscsiIntrLoginAuthenticateFails OBJECT-TYPE SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current Bakke & Venkatesen Standards Track [Page 52] RFC 7147 iSCSI MIB April 2014 DESCRIPTION "The number of times the initiator has aborted a login because the target could not be authenticated. No response is generated. If this counter is incremented, an iscsiIntrLoginFailure notification should be generated. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiInitiatorLoginStatsEntry 5 } iscsiIntrLoginNegotiateFails OBJECT-TYPE SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the initiator has aborted a login because parameter negotiation with the target failed. No response is generated. If this counter is incremented, an iscsiIntrLoginFailure notification should be generated. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 7.12, Negotiation Failures" ::= { iscsiInitiatorLoginStatsEntry 6 } iscsiIntrLoginAuthorizeFails OBJECT-TYPE SYNTAX Counter32 UNITS "failed logins" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Login Response PDUs with status 0x0202, Forbidden Target, received by this initiator. If this counter is incremented, an iscsiIntrLoginFailure notification should be generated. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE Bakke & Venkatesen Standards Track [Page 53] RFC 7147 iSCSI MIB April 2014 "RFC 7143, Section 11.13.5, Status-Class and Status-Detail" ::= { iscsiInitiatorLoginStatsEntry 7 } -- Initiator Logout Stats Table iscsiInitiatorLogoutStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiInitiatorLogoutStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "When an initiator attempts to send a Logout command, the target responds with a Logout Response that carries a status code. This table contains a list of counters of Logout Response PDUs of each status code that was received by each initiator belonging to this iSCSI instance present on this system." ::= { iscsiInitiator 3 } iscsiInitiatorLogoutStatsEntry OBJECT-TYPE SYNTAX IscsiInitiatorLogoutStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing counters of Logout Response PDUs of each status code that was generated by this initiator." AUGMENTS { iscsiInitiatorAttributesEntry } ::= { iscsiInitiatorLogoutStatsTable 1 } IscsiInitiatorLogoutStatsEntry ::= SEQUENCE { iscsiIntrLogoutNormals Counter32, iscsiIntrLogoutOthers Counter32 } iscsiIntrLogoutNormals OBJECT-TYPE SYNTAX Counter32 UNITS "normal logouts" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Logout Command PDUs generated by this initiator with reason code 0 (closes the session). If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.14.1, Reason Code" ::= { iscsiInitiatorLogoutStatsEntry 1 } Bakke & Venkatesen Standards Track [Page 54] RFC 7147 iSCSI MIB April 2014 iscsiIntrLogoutOthers OBJECT-TYPE SYNTAX Counter32 UNITS "abnormal logouts" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Logout Command PDUs generated by this initiator with any status code other than 0. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiNodeDiscontinuityTime." REFERENCE "RFC 7143, Section 11.14.1, Reason Code" ::= { iscsiInitiatorLogoutStatsEntry 2 } --********************************************************************** iscsiIntrAuthorization OBJECT IDENTIFIER ::= { iscsiObjects 9 } -- Initiator Authorization Attributes Table iscsiIntrAuthAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiIntrAuthAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of target identities that each initiator on the local system may access." ::= { iscsiIntrAuthorization 1 } iscsiIntrAuthAttributesEntry OBJECT-TYPE SYNTAX IscsiIntrAuthAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing management information applicable to a particular initiator node's authorized target identity." INDEX { iscsiInstIndex, iscsiNodeIndex, iscsiIntrAuthIndex } ::= { iscsiIntrAuthAttributesTable 1 } IscsiIntrAuthAttributesEntry ::= SEQUENCE { iscsiIntrAuthIndex Unsigned32, iscsiIntrAuthRowStatus RowStatus, iscsiIntrAuthIdentity RowPointer, iscsiIntrAuthStorageType StorageType } iscsiIntrAuthIndex OBJECT-TYPE Bakke & Venkatesen Standards Track [Page 55] RFC 7147 iSCSI MIB April 2014 SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer used to uniquely identify a particular initiator node's authorized target identity within an iSCSI instance present on the local system. This index value must not be modified or reused by an agent unless a reboot has occurred. An agent should attempt to keep this value persistent across reboots." ::= { iscsiIntrAuthAttributesEntry 1 } iscsiIntrAuthRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This field allows entries to be dynamically added and removed from this table via SNMP. When adding a row to this table, all non-Index/RowStatus objects must be set. When the value of this object is 'active', the values of the other objects in this table cannot be changed. Rows may be discarded using RowStatus." ::= { iscsiIntrAuthAttributesEntry 2 } iscsiIntrAuthIdentity OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-create STATUS current DESCRIPTION "A pointer to the corresponding user entry in the IPS-AUTH MIB module to which this initiator node should attempt to establish an iSCSI session." REFERENCE "IPS-AUTH MIB, RFC 4545, Section 7.3, ipsAuthIdentity" ::= { iscsiIntrAuthAttributesEntry 3 } iscsiIntrAuthStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this row. Rows in this table that were created through an external process (e.g., not created via this MIB) may have a storage type of readOnly or permanent. Conceptual rows having the value 'permanent' need not Bakke & Venkatesen Standards Track [Page 56] RFC 7147 iSCSI MIB April 2014 allow write access to any columnar objects in the row." DEFVAL { nonVolatile } ::= { iscsiIntrAuthAttributesEntry 4 } --********************************************************************** iscsiSession OBJECT IDENTIFIER ::= { iscsiObjects 10 } -- Session Attributes Table iscsiSessionAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiSessionAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of sessions belonging to each iSCSI instance present on the system." ::= { iscsiSession 1 } iscsiSessionAttributesEntry OBJECT-TYPE SYNTAX IscsiSessionAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing management information applicable to a particular session. If this session is a discovery session that is not attached to any particular node, the iscsiSsnNodeIndex will be zero. Otherwise, the iscsiSsnNodeIndex will have the same value as iscsiNodeIndex." INDEX { iscsiInstIndex, iscsiSsnNodeIndex, iscsiSsnIndex } ::= { iscsiSessionAttributesTable 1 } IscsiSessionAttributesEntry ::= SEQUENCE { iscsiSsnNodeIndex Unsigned32, iscsiSsnIndex Unsigned32, iscsiSsnDirection INTEGER, iscsiSsnInitiatorName IscsiName, iscsiSsnTargetName IscsiName, iscsiSsnTSIH Unsigned32, iscsiSsnISID OCTET STRING, iscsiSsnInitiatorAlias SnmpAdminString, iscsiSsnTargetAlias SnmpAdminString, iscsiSsnInitialR2T TruthValue, iscsiSsnImmediateData TruthValue, iscsiSsnType INTEGER, iscsiSsnMaxOutstandingR2T Unsigned32, Bakke & Venkatesen Standards Track [Page 57] RFC 7147 iSCSI MIB April 2014 iscsiSsnFirstBurstLength Unsigned32, iscsiSsnMaxBurstLength Unsigned32, iscsiSsnConnectionNumber Gauge32, iscsiSsnAuthIdentity RowPointer, iscsiSsnDataSequenceInOrder TruthValue, iscsiSsnDataPDUInOrder TruthValue, iscsiSsnErrorRecoveryLevel Unsigned32, iscsiSsnDiscontinuityTime TimeStamp, iscsiSsnProtocolLevel Unsigned32, iscsiSsnTaskReporting BITS } iscsiSsnNodeIndex OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer used to uniquely identify a particular node within an iSCSI instance present on the local system. For normal, non-discovery sessions, this value will map to the iscsiNodeIndex. For discovery sessions that do not have a node associated, the value 0 (zero) is used." ::= { iscsiSessionAttributesEntry 1 } iscsiSsnIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer used to uniquely identify a particular session within an iSCSI instance present on the local system. An agent should attempt to not reuse index values unless a reboot has occurred. iSCSI sessions are destroyed during a reboot; rows in this table are not persistent across reboots." ::= { iscsiSessionAttributesEntry 2 } iscsiSsnDirection OBJECT-TYPE SYNTAX INTEGER { inboundSession(1), outboundSession(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Direction of iSCSI session: inboundSession - session is established from an external Bakke & Venkatesen Standards Track [Page 58] RFC 7147 iSCSI MIB April 2014 initiator to a target within this iSCSI instance. outboundSession - session is established from an initiator within this iSCSI instance to an external target." ::= { iscsiSessionAttributesEntry 3 } iscsiSsnInitiatorName OBJECT-TYPE SYNTAX IscsiName MAX-ACCESS read-only STATUS current DESCRIPTION "If iscsiSsnDirection is Inbound, this object is a UTF-8 string that will contain the name of the remote initiator. If this session is a discovery session that does not specify a particular initiator, this object will contain a zero-length string. If iscsiSsnDirection is Outbound, this object will contain a zero-length string." ::= { iscsiSessionAttributesEntry 4 } iscsiSsnTargetName OBJECT-TYPE SYNTAX IscsiName MAX-ACCESS read-only STATUS current DESCRIPTION "If iscsiSsnDirection is Outbound, this object is a UTF-8 string that will contain the name of the remote target. If this session is a discovery session that does not specify a particular target, this object will contain a zero-length string. If iscsiSsnDirection is Inbound, this object will contain a zero-length string." ::= { iscsiSessionAttributesEntry 5 } iscsiSsnTSIH OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The target-defined identification handle for this session." REFERENCE "RFC 7143, Section 11.12.6, TSIH" ::= { iscsiSessionAttributesEntry 6 } iscsiSsnISID OBJECT-TYPE Bakke & Venkatesen Standards Track [Page 59] RFC 7147 iSCSI MIB April 2014 SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-only STATUS current DESCRIPTION "The initiator-defined portion of the iSCSI Session ID." REFERENCE "RFC 7143, Section 11.12.5, ISID" ::= { iscsiSessionAttributesEntry 7 } iscsiSsnInitiatorAlias OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A UTF-8 string that gives the alias communicated by the initiator end of the session during the login phase. If no alias exists, the value is a zero-length string." REFERENCE "RFC 7143, Section 13.7, InitiatorAlias" ::= { iscsiSessionAttributesEntry 8 } iscsiSsnTargetAlias OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A UTF-8 string that gives the alias communicated by the target end of the session during the login phase. If no alias exists, the value is a zero-length string." REFERENCE "RFC 7143, Section 13.6, TargetAlias" ::= { iscsiSessionAttributesEntry 9 } iscsiSsnInitialR2T OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "If set to true, indicates that the initiator must wait for an R2T before sending to the target. If set to false, the initiator may send data immediately, within limits set by iscsiSsnFirstBurstLength and the expected data transfer length of the request." REFERENCE "RFC 7143, Section 13.10, InitialR2T" ::= { iscsiSessionAttributesEntry 10 } Bakke & Venkatesen Standards Track [Page 60] RFC 7147 iSCSI MIB April 2014 iscsiSsnImmediateData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the initiator and target have agreed to support immediate data on this session." REFERENCE "RFC 7143, Section 13.11, ImmediateData" ::= { iscsiSessionAttributesEntry 11 } iscsiSsnType OBJECT-TYPE SYNTAX INTEGER { normalSession(1), discoverySession(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of iSCSI session: normalSession - session is a normal iSCSI session discoverySession - session is being used only for discovery." REFERENCE "RFC 7143, Section 13.21, SessionType" ::= { iscsiSessionAttributesEntry 12 } iscsiSsnMaxOutstandingR2T OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "R2Ts" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of outstanding requests-to-transmit (R2Ts) per iSCSI task within this session." REFERENCE "RFC 7143, Section 13.17, MaxOutstandingR2T" ::= { iscsiSessionAttributesEntry 13 } iscsiSsnFirstBurstLength OBJECT-TYPE SYNTAX Unsigned32 (512..16777215) UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum length supported for unsolicited data sent within this session." REFERENCE Bakke & Venkatesen Standards Track [Page 61] RFC 7147 iSCSI MIB April 2014 "RFC 7143, Section 13.14, FirstBurstLength" ::= { iscsiSessionAttributesEntry 14 } iscsiSsnMaxBurstLength OBJECT-TYPE SYNTAX Unsigned32 (512..16777215) UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of bytes that can be sent within a single sequence of Data-In or Data-Out PDUs." REFERENCE "RFC 7143, Section 13.13, MaxBurstLength" ::= { iscsiSessionAttributesEntry 15 } iscsiSsnConnectionNumber OBJECT-TYPE SYNTAX Gauge32 (1..65535) UNITS "connections" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transport protocol connections that currently belong to this session." ::= { iscsiSessionAttributesEntry 16 } iscsiSsnAuthIdentity OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains a pointer to a row in the IPS-AUTH MIB module that identifies the authentication identity being used on this session, as communicated during the login phase." REFERENCE "IPS-AUTH MIB, RFC 4545, Section 7.3, ipsAuthIdentity" ::= { iscsiSessionAttributesEntry 17 } iscsiSsnDataSequenceInOrder OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "False indicates that iSCSI data PDU sequences may be transferred in any order. True indicates that data PDU sequences must be transferred using continuously increasing offsets, except during error recovery." Bakke & Venkatesen Standards Track [Page 62] RFC 7147 iSCSI MIB April 2014 REFERENCE "RFC 7143, Section 13.19, DataSequenceInOrder" ::= { iscsiSessionAttributesEntry 18 } iscsiSsnDataPDUInOrder OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "False indicates that iSCSI data PDUs within sequences may be in any order. True indicates that data PDUs within sequences must be at continuously increasing addresses, with no gaps or overlay between PDUs. Default is true." REFERENCE "RFC 7143, Section 13.18, DataPDUInOrder" ::= { iscsiSessionAttributesEntry 19 } iscsiSsnErrorRecoveryLevel OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The level of error recovery negotiated between the initiator and the target. Higher numbers represent more detailed recovery schemes." REFERENCE "RFC 7143, Section 13.20, ErrorRecoveryLevel" ::= { iscsiSessionAttributesEntry 20 } iscsiSsnDiscontinuityTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of SysUpTime on the most recent occasion at which any one or more of this session's counters suffered a discontinuity. When a session is established, and this object is created, it is initialized to the current value of SysUpTime." ::= { iscsiSessionAttributesEntry 21 } iscsiSsnProtocolLevel OBJECT-TYPE SYNTAX Unsigned32 (0..31) MAX-ACCESS read-only STATUS current DESCRIPTION Bakke & Venkatesen Standards Track [Page 63] RFC 7147 iSCSI MIB April 2014 "The iSCSI protocol level negotiated for this session." REFERENCE "RFC 7144, Section 7.1.1, iSCSIProtocolLevel" DEFVAL { 1 } ::= { iscsiSessionAttributesEntry 22 } iscsiSsnTaskReporting OBJECT-TYPE SYNTAX BITS { taskReportingRfc3720(0), taskReportingResponseFence(1), taskReportingFastAbort(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This key is used to negotiate the task completion reporting semantics from the SCSI target. Default value is taskReportingRfc3720." REFERENCE "RFC 7143, Section 13.23, TaskReporting" ::= { iscsiSessionAttributesEntry 23 } -- Session Stats Table iscsiSessionStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiSessionStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of general iSCSI traffic counters for each of the sessions present on the system." ::= { iscsiSession 2 } iscsiSessionStatsEntry OBJECT-TYPE SYNTAX IscsiSessionStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing general iSCSI traffic counters for a particular session." AUGMENTS { iscsiSessionAttributesEntry } ::= { iscsiSessionStatsTable 1 } IscsiSessionStatsEntry ::= SEQUENCE { iscsiSsnCmdPDUs Counter32, Bakke & Venkatesen Standards Track [Page 64] RFC 7147 iSCSI MIB April 2014 iscsiSsnRspPDUs Counter32, iscsiSsnTxDataOctets Counter64, iscsiSsnRxDataOctets Counter64, iscsiSsnLCTxDataOctets Counter32, iscsiSsnLCRxDataOctets Counter32, iscsiSsnNopReceivedPDUs Counter32, iscsiSsnNopSentPDUs Counter32 } iscsiSsnCmdPDUs OBJECT-TYPE SYNTAX Counter32 UNITS "PDUs" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Command PDUs transferred on this session. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiSsnDiscontinuityTime." ::= { iscsiSessionStatsEntry 1 } iscsiSsnRspPDUs OBJECT-TYPE SYNTAX Counter32 UNITS "PDUs" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Response PDUs transferred on this session. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiSsnDiscontinuityTime." ::= { iscsiSessionStatsEntry 2 } iscsiSsnTxDataOctets OBJECT-TYPE SYNTAX Counter64 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of data octets that were transmitted by the local iSCSI node on this session. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiSsnDiscontinuityTime." ::= { iscsiSessionStatsEntry 3 } iscsiSsnRxDataOctets OBJECT-TYPE SYNTAX Counter64 UNITS "octets" MAX-ACCESS read-only STATUS current Bakke & Venkatesen Standards Track [Page 65] RFC 7147 iSCSI MIB April 2014 DESCRIPTION "The count of data octets that were received by the local iSCSI node on this session. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiSsnDiscontinuityTime." ::= { iscsiSessionStatsEntry 4 } iscsiSsnLCTxDataOctets OBJECT-TYPE SYNTAX Counter32 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "A Low-Capacity shadow object of iscsiSsnTxDataOctets for those systems that are accessible via SNMPv1 only. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiSsnDiscontinuityTime." ::= { iscsiSessionStatsEntry 5 } iscsiSsnLCRxDataOctets OBJECT-TYPE SYNTAX Counter32 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "A Low-Capacity shadow object of iscsiSsnRxDataOctets for those systems which are accessible via SNMPv1 only. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiSsnDiscontinuityTime." ::= { iscsiSessionStatsEntry 6 } iscsiSsnNopReceivedPDUs OBJECT-TYPE SYNTAX Counter32 UNITS "PDUs" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of NOP-In or NOP-Out PDUs received on this session. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiSsnDiscontinuityTime." ::= { iscsiSessionStatsEntry 7 } iscsiSsnNopSentPDUs OBJECT-TYPE SYNTAX Counter32 UNITS "PDUs" MAX-ACCESS read-only STATUS current DESCRIPTION Bakke & Venkatesen Standards Track [Page 66] RFC 7147 iSCSI MIB April 2014 "The count of NOP-In or NOP-Out PDUs sent on this session. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiSsnDiscontinuityTime." ::= { iscsiSessionStatsEntry 8 } -- Session Connection Error Stats Table iscsiSessionCxnErrorStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiSessionCxnErrorStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of error counters for each of the sessions present on this system." ::= { iscsiSession 3 } iscsiSessionCxnErrorStatsEntry OBJECT-TYPE SYNTAX IscsiSessionCxnErrorStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing error counters for a particular session." AUGMENTS { iscsiSessionAttributesEntry } ::= { iscsiSessionCxnErrorStatsTable 1 } IscsiSessionCxnErrorStatsEntry ::= SEQUENCE { iscsiSsnCxnDigestErrors Counter32, iscsiSsnCxnTimeoutErrors Counter32 } iscsiSsnCxnDigestErrors OBJECT-TYPE SYNTAX Counter32 UNITS "PDUs" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of PDUs that were received on the session and contained header or data digest errors. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiSsnDiscontinuityTime. This counter is most likely provided when the error-recovery level is 1 or 2" REFERENCE "RFC 7143, Section 7.8, Digest Errors" ::= { iscsiSessionCxnErrorStatsEntry 1 } iscsiSsnCxnTimeoutErrors OBJECT-TYPE Bakke & Venkatesen Standards Track [Page 67] RFC 7147 iSCSI MIB April 2014 SYNTAX Counter32 UNITS "connections" MAX-ACCESS read-only STATUS current DESCRIPTION "The count of connections within this session that have been terminated due to timeout. If this counter has suffered a discontinuity, the time of the last discontinuity is indicated in iscsiSsnDiscontinuityTime. This counter is most likely provided when the error-recovery level is 2" REFERENCE "RFC 7143, Section 7.5, Connection Timeout Management" ::= { iscsiSessionCxnErrorStatsEntry 2 } --********************************************************************** iscsiConnection OBJECT IDENTIFIER ::= { iscsiObjects 11 } -- Connection Attributes Table iscsiConnectionAttributesTable OBJECT-TYPE SYNTAX SEQUENCE OF IscsiConnectionAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of connections belonging to each iSCSI instance present on the system." ::= { iscsiConnection 1 } iscsiConnectionAttributesEntry OBJECT-TYPE SYNTAX IscsiConnectionAttributesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) containing management information applicable to a particular connection." INDEX { iscsiInstIndex, iscsiSsnNodeIndex, iscsiSsnIndex, iscsiCxnIndex } ::= { iscsiConnectionAttributesTable 1 } IscsiConnectionAttributesEntry ::= SEQUENCE { iscsiCxnIndex Unsigned32, iscsiCxnCid Unsigned32, iscsiCxnState INTEGER, iscsiCxnAddrType InetAddressType, iscsiCxnLocalAddr InetAddress, iscsiCxnProtocol IscsiTransportProtocol, Bakke & Venkatesen Standards Track [Page 68] RFC 7147 iSCSI MIB April 2014 iscsiCxnLocalPort InetPortNumber, iscsiCxnRemoteAddr InetAddress, iscsiCxnRemotePort InetPortNumber, iscsiCxnMaxRecvDataSegLength Unsigned32, iscsiCxnMaxXmitDataSegLength Unsigned32, iscsiCxnHeaderIntegrity IscsiDigestMethod, iscsiCxnDataIntegrity IscsiDigestMethod, iscsiCxnRecvMarker TruthValue, iscsiCxnSendMarker TruthValue, iscsiCxnVersionActive Unsigned32 } iscsiCxnIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer used to uniquely identify a particular connection of a particular session within an iSCSI instance present on the local system. An agent should attempt to not reuse index values unless a reboot has occurred. iSCSI connections are destroyed during a reboot; rows in this table are not persistent across reboots." ::= { iscsiConnectionAttributesEntry 1 } iscsiCxnCid OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The iSCSI Connection ID for this connection." ::= { iscsiConnectionAttributesEntry 2 } iscsiCxnState OBJECT-TYPE SYNTAX INTEGER { login(1), full(2), logout(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of this connection, from an iSCSI negotiation point of view. Here are the states: login - The transport protocol connection has been established, but a valid iSCSI login response with the final bit set Bakke & Venkatesen Standards Track [Page 69] RFC 7147 iSCSI MIB April 2014 has not been sent or received. full - A valid iSCSI login response with the final bit set has been sent or received. logout - A valid iSCSI logout command has been sent or received, but the transport protocol connection has not yet been closed." ::= { iscsiConnectionAttributesEntry 3 } iscsiCxnAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet Network Addresses contained in the corresponding instances of iscsiCxnLocalAddr and iscsiCxnRemoteAddr. The value 'dns' is not allowed." ::= { iscsiConnectionAttributesEntry 4 } iscsiCxnLocalAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The local Internet Network Address, of the type specified by iscsiCxnAddrType, used by this connection." ::= { iscsiConnectionAttributesEntry 5 } iscsiCxnProtocol OBJECT-TYPE SYNTAX IscsiTransportProtocol MAX-ACCESS read-only STATUS current DESCRIPTION "The transport protocol over which this connection is running." ::= { iscsiConnectionAttributesEntry 6 } iscsiCxnLocalPort OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The local transport protocol port used by this connection. This object cannot have the value zero, since it represents an established connection." ::= { iscsiConnectionAttributesEntry 7 } iscsiCxnRemoteAddr OBJECT-TYPE Bakke & Venkatesen Standards Track [Page 70] RFC 7147 iSCSI MIB April 2014 SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The remote Internet Network Address, of the type specified by iscsiCxnAddrType, used by this connection." ::= { iscsiConnectionAttributesEntry 8 } iscsiCxnRemotePort OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The remote transport protocol port used by this connection. This object cannot have the value zero, since it represents an established connection." ::= { iscsiConnectionAttributesEntry 9 } iscsiCxnMaxRecvDataSegLength OBJECT-TYPE SYNTAX Unsigned32 (512..16777215) UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum data payload size supported for command or data PDUs able to be received on this connection." REFERENCE "RFC 7143, Section 13.12, MaxRecvDataSegmentLength" ::= { iscsiConnectionAttributesEntry 10 } iscsiCxnMaxXmitDataSegLength OBJECT-TYPE SYNTAX Unsigned32 (512..16777215) UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum data payload size supported for command or data PDUs to be sent on this connection." REFERENCE "RFC 7143, Section 13.12, MaxRecvDataSegmentLength" ::= { iscsiConnectionAttributesEntry 11 } iscsiCxnHeaderIntegrity OBJECT-TYPE SYNTAX IscsiDigestMethod MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the iSCSI header Bakke & Venkatesen Standards Track [Page 71] RFC 7147 iSCSI MIB April 2014 digest scheme in use within this connection." ::= { iscsiConnectionAttributesEntry 12 } iscsiCxnDataIntegrity OBJECT-TYPE SYNTAX IscsiDigestMethod MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the iSCSI data digest scheme in use within this connection." ::= { iscsiConnectionAttributesEntry 13 } iscsiCxnRecvMarker OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object indicates whether or not this connection is receiving markers in its incoming data stream." REFERENCE "RFC 7143, Section 13.25, Obsoleted Keys." ::= { iscsiConnectionAttributesEntry 14 } iscsiCxnSendMarker OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object indicates whether or not this connection is inserting markers in its outgoing data stream." REFERENCE "RFC 7143, Section 13.25, Obsoleted Keys." ::= { iscsiConnectionAttributesEntry 15 } iscsiCxnVersionActive OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Active version number of the iSCSI specification negotiated on this connection." REFERENCE "RFC 7143, Section 11.12, Login Request" ::= { iscsiConnectionAttributesEntry 16 } --********************************************************************** -- Notifications Bakke & Venkatesen Standards Track [Page 72] RFC 7147 iSCSI MIB April 2014 iscsiTgtLoginFailure NOTIFICATION-TYPE OBJECTS { iscsiTgtLoginFailures, iscsiTgtLastFailureType, iscsiTgtLastIntrFailureName, iscsiTgtLastIntrFailureAddrType, iscsiTgtLastIntrFailureAddr, iscsiTgtLastIntrFailurePort } STATUS current DESCRIPTION "Sent when a login is failed by a target. To avoid sending an excessive number of notifications due to multiple errors counted, an SNMP agent implementing this notification SHOULD NOT send more than 3 notifications of this type in any 10-second time period." ::= { iscsiNotifications 1 } iscsiIntrLoginFailure NOTIFICATION-TYPE OBJECTS { iscsiIntrLoginFailures, iscsiIntrLastFailureType, iscsiIntrLastTgtFailureName, iscsiIntrLastTgtFailureAddrType, iscsiIntrLastTgtFailureAddr, iscsiIntrLastTgtFailurePort } STATUS current DESCRIPTION "Sent when a login is failed by an initiator. To avoid sending an excessive number of notifications due to multiple errors counted, an SNMP agent implementing this notification SHOULD NOT send more than 3 notifications of this type in any 10-second time period." ::= { iscsiNotifications 2 } iscsiInstSessionFailure NOTIFICATION-TYPE OBJECTS { iscsiInstSsnFailures, iscsiInstLastSsnFailureType, iscsiInstLastSsnRmtNodeName } STATUS current DESCRIPTION "Sent when an active session is failed by either the initiator or the target. Bakke & Venkatesen Standards Track [Page 73] RFC 7147 iSCSI MIB April 2014 To avoid sending an excessive number of notifications due to multiple errors counted, an SNMP agent implementing this notification SHOULD NOT send more than 3 notifications of this type in any 10-second time period." ::= { iscsiNotifications 3 } --********************************************************************** -- Conformance Statements iscsiCompliances OBJECT IDENTIFIER ::= { iscsiConformance 1 } iscsiGroups OBJECT IDENTIFIER ::= { iscsiConformance 2 } iscsiInstanceAttributesGroup OBJECT-GROUP OBJECTS { iscsiInstDescr, iscsiInstVersionMin, iscsiInstVersionMax, iscsiInstVendorID, iscsiInstVendorVersion, iscsiInstPortalNumber, iscsiInstNodeNumber, iscsiInstSessionNumber, iscsiInstSsnFailures, iscsiInstLastSsnFailureType, iscsiInstLastSsnRmtNodeName, iscsiInstDiscontinuityTime, iscsiInstXNodeArchitecture } STATUS current DESCRIPTION "A collection of objects providing information about iSCSI instances." ::= { iscsiGroups 1 } iscsiInstanceSsnErrorStatsGroup OBJECT-GROUP OBJECTS { iscsiInstSsnDigestErrors, iscsiInstSsnCxnTimeoutErrors, iscsiInstSsnFormatErrors } STATUS current DESCRIPTION "A collection of objects providing information about errors that have caused a session failure for an iSCSI instance." ::= { iscsiGroups 2 } Bakke & Venkatesen Standards Track [Page 74] RFC 7147 iSCSI MIB April 2014 iscsiPortalAttributesGroup OBJECT-GROUP OBJECTS { iscsiPortalRowStatus, iscsiPortalStorageType, iscsiPortalRoles, iscsiPortalAddrType, iscsiPortalAddr, iscsiPortalProtocol, iscsiPortalMaxRecvDataSegLength, iscsiPortalPrimaryHdrDigest, iscsiPortalPrimaryDataDigest, iscsiPortalSecondaryHdrDigest, iscsiPortalSecondaryDataDigest, iscsiPortalRecvMarker } STATUS deprecated DESCRIPTION "A collection of objects providing information about the transport protocol endpoints of the local targets. This object group is deprecated because the marker key is obsolete." REFERENCE "RFC 7143, Section 13.25, Obsoleted Keys." ::= { iscsiGroups 3 } iscsiTgtPortalAttributesGroup OBJECT-GROUP OBJECTS { iscsiTgtPortalPort, iscsiTgtPortalTag } STATUS current DESCRIPTION "A collection of objects providing information about the transport protocol endpoints of the local targets." ::= { iscsiGroups 4 } iscsiIntrPortalAttributesGroup OBJECT-GROUP OBJECTS { iscsiIntrPortalTag } STATUS current DESCRIPTION "An object providing information about the portal tags used by the local initiators." ::= { iscsiGroups 5 } iscsiNodeAttributesGroup OBJECT-GROUP OBJECTS { Bakke & Venkatesen Standards Track [Page 75] RFC 7147 iSCSI MIB April 2014 iscsiNodeName, iscsiNodeAlias, iscsiNodeRoles, iscsiNodeTransportType, iscsiNodeInitialR2T, iscsiNodeImmediateData, iscsiNodeMaxOutstandingR2T, iscsiNodeFirstBurstLength, iscsiNodeMaxBurstLength, iscsiNodeMaxConnections, iscsiNodeDataSequenceInOrder, iscsiNodeDataPDUInOrder, iscsiNodeDefaultTime2Wait, iscsiNodeDefaultTime2Retain, iscsiNodeErrorRecoveryLevel, iscsiNodeDiscontinuityTime, iscsiNodeStorageType } STATUS current DESCRIPTION "A collection of objects providing information about all local targets." ::= { iscsiGroups 6 } iscsiTargetAttributesGroup OBJECT-GROUP OBJECTS { iscsiTgtLoginFailures, iscsiTgtLastFailureTime, iscsiTgtLastFailureType, iscsiTgtLastIntrFailureName, iscsiTgtLastIntrFailureAddrType, iscsiTgtLastIntrFailureAddr } STATUS current DESCRIPTION "A collection of objects providing information about all local targets." ::= { iscsiGroups 7 } iscsiTargetLoginStatsGroup OBJECT-GROUP OBJECTS { iscsiTgtLoginAccepts, iscsiTgtLoginOtherFails, iscsiTgtLoginRedirects, iscsiTgtLoginAuthorizeFails, iscsiTgtLoginAuthenticateFails, iscsiTgtLoginNegotiateFails } Bakke & Venkatesen Standards Track [Page 76] RFC 7147 iSCSI MIB April 2014 STATUS current DESCRIPTION "A collection of objects providing information about all login attempts by remote initiators to local targets." ::= { iscsiGroups 8 } iscsiTargetLogoutStatsGroup OBJECT-GROUP OBJECTS { iscsiTgtLogoutNormals, iscsiTgtLogoutOthers } STATUS current DESCRIPTION "A collection of objects providing information about all logout events between remote initiators and local targets." ::= { iscsiGroups 9 } iscsiTargetAuthGroup OBJECT-GROUP OBJECTS { iscsiTgtAuthRowStatus, iscsiTgtAuthStorageType, iscsiTgtAuthIdentity } STATUS current DESCRIPTION "A collection of objects providing information about all remote initiators that are authorized to connect to local targets." ::= { iscsiGroups 10 } iscsiInitiatorAttributesGroup OBJECT-GROUP OBJECTS { iscsiIntrLoginFailures, iscsiIntrLastFailureTime, iscsiIntrLastFailureType, iscsiIntrLastTgtFailureName, iscsiIntrLastTgtFailureAddrType, iscsiIntrLastTgtFailureAddr } STATUS current DESCRIPTION "A collection of objects providing information about all local initiators." ::= { iscsiGroups 11 } iscsiInitiatorLoginStatsGroup OBJECT-GROUP OBJECTS { iscsiIntrLoginAcceptRsps, Bakke & Venkatesen Standards Track [Page 77] RFC 7147 iSCSI MIB April 2014 iscsiIntrLoginOtherFailRsps, iscsiIntrLoginRedirectRsps, iscsiIntrLoginAuthFailRsps, iscsiIntrLoginAuthenticateFails, iscsiIntrLoginNegotiateFails, iscsiIntrLoginAuthorizeFails } STATUS current DESCRIPTION "A collection of objects providing information about all login attempts by local initiators to remote targets." ::= { iscsiGroups 12 } iscsiInitiatorLogoutStatsGroup OBJECT-GROUP OBJECTS { iscsiIntrLogoutNormals, iscsiIntrLogoutOthers } STATUS current DESCRIPTION "A collection of objects providing information about all logout events between local initiators and remote targets." ::= { iscsiGroups 13 } iscsiInitiatorAuthGroup OBJECT-GROUP OBJECTS { iscsiIntrAuthRowStatus, iscsiIntrAuthStorageType, iscsiIntrAuthIdentity } STATUS current DESCRIPTION "A collection of objects providing information about all remote targets that are initiators of the local system that they are authorized to access." ::= { iscsiGroups 14 } iscsiSessionAttributesGroup OBJECT-GROUP OBJECTS { iscsiSsnDirection, iscsiSsnInitiatorName, iscsiSsnTargetName, iscsiSsnTSIH, iscsiSsnISID, iscsiSsnInitiatorAlias, iscsiSsnTargetAlias, iscsiSsnInitialR2T, iscsiSsnImmediateData, Bakke & Venkatesen Standards Track [Page 78] RFC 7147 iSCSI MIB April 2014 iscsiSsnType, iscsiSsnMaxOutstandingR2T, iscsiSsnFirstBurstLength, iscsiSsnMaxBurstLength, iscsiSsnConnectionNumber, iscsiSsnAuthIdentity, iscsiSsnDataSequenceInOrder, iscsiSsnDataPDUInOrder, iscsiSsnErrorRecoveryLevel, iscsiSsnDiscontinuityTime, iscsiSsnProtocolLevel, iscsiSsnTaskReporting } STATUS current DESCRIPTION "A collection of objects providing information applicable to all sessions." ::= { iscsiGroups 15 } iscsiSessionPDUStatsGroup OBJECT-GROUP OBJECTS { iscsiSsnCmdPDUs, iscsiSsnRspPDUs } STATUS current DESCRIPTION "A collection of objects providing information about PDU traffic for each session." ::= { iscsiGroups 16 } iscsiSessionOctetStatsGroup OBJECT-GROUP OBJECTS { iscsiSsnTxDataOctets, iscsiSsnRxDataOctets } STATUS current DESCRIPTION "A collection of objects providing information about octet traffic for each session using a Counter64 data type." ::= { iscsiGroups 17 } iscsiSessionLCOctetStatsGroup OBJECT-GROUP OBJECTS { iscsiSsnLCTxDataOctets, iscsiSsnLCRxDataOctets } STATUS current DESCRIPTION Bakke & Venkatesen Standards Track [Page 79] RFC 7147 iSCSI MIB April 2014 "A collection of objects providing information about octet traffic for each session using a Counter32 data type." ::= { iscsiGroups 18 } iscsiSessionCxnErrorStatsGroup OBJECT-GROUP OBJECTS { iscsiSsnCxnDigestErrors, iscsiSsnCxnTimeoutErrors } STATUS current DESCRIPTION "A collection of objects providing information about connection errors for all sessions." ::= { iscsiGroups 19 } iscsiConnectionAttributesGroup OBJECT-GROUP OBJECTS { iscsiCxnCid, iscsiCxnState, iscsiCxnProtocol, iscsiCxnAddrType, iscsiCxnLocalAddr, iscsiCxnLocalPort, iscsiCxnRemoteAddr, iscsiCxnRemotePort, iscsiCxnMaxRecvDataSegLength, iscsiCxnMaxXmitDataSegLength, iscsiCxnHeaderIntegrity, iscsiCxnDataIntegrity, iscsiCxnRecvMarker, iscsiCxnSendMarker, iscsiCxnVersionActive } STATUS deprecated DESCRIPTION "A collection of objects providing information about all connections used by all sessions. This object group is deprecated because the marker key is obsolete." REFERENCE "RFC 7143, Section 13.25, Obsoleted Keys." ::= { iscsiGroups 20 } iscsiTgtLgnNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { iscsiTgtLoginFailure } STATUS current Bakke & Venkatesen Standards Track [Page 80] RFC 7147 iSCSI MIB April 2014 DESCRIPTION "A collection of notifications that indicate a login failure from a remote initiator to a local target." ::= { iscsiGroups 21 } iscsiIntrLgnNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { iscsiIntrLoginFailure } STATUS current DESCRIPTION "A collection of notifications that indicate a login failure from a local initiator to a remote target." ::= { iscsiGroups 22 } iscsiSsnFlrNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { iscsiInstSessionFailure } STATUS current DESCRIPTION "A collection of notifications that indicate session failures occurring after login." ::= { iscsiGroups 23 } iscsiPortalAttributesGroupV2 OBJECT-GROUP OBJECTS { iscsiPortalRowStatus, iscsiPortalStorageType, iscsiPortalRoles, iscsiPortalAddrType, iscsiPortalAddr, iscsiPortalProtocol, iscsiPortalMaxRecvDataSegLength, iscsiPortalPrimaryHdrDigest, iscsiPortalPrimaryDataDigest, iscsiPortalSecondaryHdrDigest, iscsiPortalSecondaryDataDigest } STATUS current DESCRIPTION "A collection of objects providing information about the transport protocol endpoints of the local targets." ::= { iscsiGroups 24 } iscsiConnectionAttributesGroupV2 OBJECT-GROUP OBJECTS { iscsiCxnCid, Bakke & Venkatesen Standards Track [Page 81] RFC 7147 iSCSI MIB April 2014 iscsiCxnState, iscsiCxnProtocol, iscsiCxnAddrType, iscsiCxnLocalAddr, iscsiCxnLocalPort, iscsiCxnRemoteAddr, iscsiCxnRemotePort, iscsiCxnMaxRecvDataSegLength, iscsiCxnMaxXmitDataSegLength, iscsiCxnHeaderIntegrity, iscsiCxnDataIntegrity, iscsiCxnVersionActive } STATUS current DESCRIPTION "A collection of objects providing information about all connections used by all sessions." ::= { iscsiGroups 25 } iscsiNewObjectsV2 OBJECT-GROUP OBJECTS { iscsiInstXNodeArchitecture, iscsiSsnTaskReporting, iscsiSsnProtocolLevel, iscsiSsnNopReceivedPDUs, iscsiSsnNopSentPDUs, iscsiIntrLastTgtFailurePort, iscsiTgtLastIntrFailurePort, iscsiPortalDescr, iscsiInstSsnTgtUnmappedErrors, iscsiTgtLogoutCxnClosed, iscsiTgtLogoutCxnRemoved } STATUS current DESCRIPTION "A collection of objects added in the second version of the iSCSI MIB." ::= { iscsiGroups 26 } --********************************************************************** iscsiComplianceV1 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "Initial version of compliance statement. Bakke & Venkatesen Standards Track [Page 82] RFC 7147 iSCSI MIB April 2014 If an implementation can be both a target and an initiator, all groups are mandatory. This module compliance is deprecated because the marker keys are obsolete." REFERENCE "RFC 7143, Section 13.25, Obsoleted Keys." MODULE -- this module MANDATORY-GROUPS { iscsiInstanceAttributesGroup, iscsiInstanceSsnErrorStatsGroup, iscsiPortalAttributesGroup, iscsiNodeAttributesGroup, iscsiSessionAttributesGroup, iscsiSessionPDUStatsGroup, iscsiSessionCxnErrorStatsGroup, iscsiConnectionAttributesGroup, iscsiSsnFlrNotificationsGroup } -- Conditionally mandatory groups depending on the ability -- to support Counter64 data types and/or to provide counter -- information to SNMPv1 applications. GROUP iscsiSessionOctetStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that can support Counter64 data types." GROUP iscsiSessionLCOctetStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that provide information to SNMPv1-only applications; this includes agents that cannot support Counter64 data types." -- Conditionally mandatory groups to be included with -- the mandatory groups when the implementation has -- iSCSI target facilities. GROUP iscsiTgtPortalAttributesGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." OBJECT iscsiPortalMaxRecvDataSegLength MIN-ACCESS read-only DESCRIPTION "Write access is not required." Bakke & Venkatesen Standards Track [Page 83] RFC 7147 iSCSI MIB April 2014 OBJECT iscsiNodeStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required; an implementation may choose to allow this object to be set to 'volatile' or 'nonVolatile'." GROUP iscsiTargetAttributesGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." GROUP iscsiTargetLoginStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." GROUP iscsiTargetLogoutStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." GROUP iscsiTgtLgnNotificationsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." GROUP iscsiTargetAuthGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." -- Conditionally mandatory groups to be included with -- the mandatory groups when the implementation has -- iSCSI initiator facilities. GROUP iscsiIntrPortalAttributesGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." GROUP iscsiInitiatorAttributesGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." GROUP iscsiInitiatorLoginStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations Bakke & Venkatesen Standards Track [Page 84] RFC 7147 iSCSI MIB April 2014 that have iSCSI initiator facilities." GROUP iscsiInitiatorLogoutStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." GROUP iscsiIntrLgnNotificationsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." GROUP iscsiInitiatorAuthGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." OBJECT iscsiNodeErrorRecoveryLevel SYNTAX Unsigned32 (0..2) DESCRIPTION "Only values 0-2 are defined at present." ::= { iscsiCompliances 1 } iscsiComplianceV2 MODULE-COMPLIANCE STATUS current DESCRIPTION "Version 2 of compliance statement based on this revised version of the MIB module. If an implementation can be both a target and an initiator, all groups are mandatory." MODULE -- this module MANDATORY-GROUPS { iscsiInstanceAttributesGroup, iscsiInstanceSsnErrorStatsGroup, iscsiPortalAttributesGroupV2, iscsiNodeAttributesGroup, iscsiSessionAttributesGroup, iscsiSessionPDUStatsGroup, iscsiSessionCxnErrorStatsGroup, iscsiConnectionAttributesGroupV2, iscsiSsnFlrNotificationsGroup } -- Conditionally mandatory groups depending on the ability -- to support Counter64 data types and/or to provide counter -- information to SNMPv1 applications. Bakke & Venkatesen Standards Track [Page 85] RFC 7147 iSCSI MIB April 2014 GROUP iscsiSessionOctetStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that can support Counter64 data types." GROUP iscsiSessionLCOctetStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that provide information to SNMPv1-only applications; this includes agents that cannot support Counter64 data types." -- Conditionally mandatory groups to be included with -- the mandatory groups when the implementation has -- iSCSI target facilities. GROUP iscsiTgtPortalAttributesGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." OBJECT iscsiPortalMaxRecvDataSegLength MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT iscsiNodeStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required; an implementation may choose to allow this object to be set to 'volatile' or 'nonVolatile'." GROUP iscsiTargetAttributesGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." GROUP iscsiTargetLoginStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." GROUP iscsiTargetLogoutStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." Bakke & Venkatesen Standards Track [Page 86] RFC 7147 iSCSI MIB April 2014 GROUP iscsiTgtLgnNotificationsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." GROUP iscsiTargetAuthGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI target facilities." -- Conditionally mandatory groups to be included with -- the mandatory groups when the implementation has -- iSCSI initiator facilities. GROUP iscsiIntrPortalAttributesGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." GROUP iscsiInitiatorAttributesGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." GROUP iscsiInitiatorLoginStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." GROUP iscsiInitiatorLogoutStatsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." GROUP iscsiIntrLgnNotificationsGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." GROUP iscsiInitiatorAuthGroup DESCRIPTION "This group is mandatory for all iSCSI implementations that have iSCSI initiator facilities." OBJECT iscsiNodeErrorRecoveryLevel SYNTAX Unsigned32 (0..2) DESCRIPTION "Only values 0-2 are defined at present." Bakke & Venkatesen Standards Track [Page 87] RFC 7147 iSCSI MIB April 2014 GROUP iscsiNewObjectsV2 DESCRIPTION "This group is mandatory for all iSCSI implementations that support a value of the iSCSIProtocolLevel key of 2 or greater." ::= { iscsiCompliances 2 } END 8. Security Considerations There are a number of management objects defined in this MIB module with a MAX-ACCESS clause of read-write and/or read-create. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations. These are the tables and objects and their sensitivity/vulnerability: iscsiPortalAttributesTable, iscsiTgtPortalAttributesTable, and iscsiIntrPortalAttributesTable can be used to add or remove IP addresses to be used by iSCSI. iscsiTgtAuthAttributesTable entries can be added or removed, to allow or disallow access to a target by an initiator. Some of the readable objects in this MIB module (i.e., objects with a MAX-ACCESS other than not-accessible) may be considered sensitive or vulnerable in some network environments. It is thus important to control even GET and/or NOTIFY access to these objects and possibly to even encrypt the values of these objects when sending them over the network via SNMP. These are the tables and objects and their sensitivity/vulnerability: iscsiNodeAttributesTable, iscsiTargetAttributesTable, and iscsiTgtAuthorization can be used to glean information needed to make connections to the iSCSI targets this module represents. However, it is the responsibility of the initiators and targets involved to authenticate each other to ensure that an inappropriately advertised or discovered initiator or target does not compromise their security. These issues are discussed in [RFC7143]. Bakke & Venkatesen Standards Track [Page 88] RFC 7147 iSCSI MIB April 2014 SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example by using IPsec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module. Implementations SHOULD provide the security features described by the SNMPv3 framework (see [RFC3410]), and implementations claiming compliance to the SNMPv3 standard MUST include full support for authentication and privacy via the User-based Security Model (USM) [RFC3414] with the AES cipher algorithm [RFC3826]. Implementations MAY also provide support for the Transport Security Model (TSM) [RFC5591] in combination with a secure transport such as SSH [RFC5592] or TLS/DTLS [RFC6353]. Further, deployment of SNMP versions prior to SNMPv3 is NOT RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic security. It is then a customer/operator responsibility to ensure that the SNMP entity giving access to an instance of this MIB module is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them. 9. IANA Considerations The MIB module in this document uses the following IANA-assigned OBJECT IDENTIFIER value recorded in the "SMI Network Management MGMT Codes Internet-standard MIB" registry: Descriptor OBJECT IDENTIFIER value ---------- ----------------------- iscsiMibModule { mib-2 142 } IANA has updated the reference for the mib-2 142 identifier to refer to this document. 10. References 10.1. Normative References [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, March 1997. [RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J. Schoenwaelder, Ed., "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999. Bakke & Venkatesen Standards Track [Page 89] RFC 7147 iSCSI MIB April 2014 [RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J. Schoenwaelder, Ed., "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999. [RFC2580] McCloghrie, K., Ed., Perkins, D., Ed., and J. Schoenwaelder, Ed., "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999. [RFC3411] Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks", STD 62, RFC 3411, December 2002. [RFC3414] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)", STD 62, RFC 3414, December 2002. [RFC3720] Satran, J., Meth, K., Sapuntzakis, C., Chadalapaka, M., and E. Zeidner, "Internet Small Computer Systems Interface (iSCSI)", RFC 3720, April 2004. [RFC3826] Blumenthal, U., Maino, F., and K. McCloghrie, "The Advanced Encryption Standard (AES) Cipher Algorithm in the SNMP User-based Security Model", RFC 3826, June 2004. [RFC4001] Daniele, M., Haberman, B., Routhier, S., and J. Schoenwaelder, "Textual Conventions for Internet Network Addresses", RFC 4001, February 2005. [RFC4545] Bakke, M. and J. Muchow, "Definitions of Managed Objects for IP Storage User Identity Authorization", RFC 4545, May 2006. [RFC5591] Harrington, D. and W. Hardaker, "Transport Security Model for the Simple Network Management Protocol (SNMP)", RFC 5591, June 2009. [RFC5592] Harrington, D., Salowey, J., and W. Hardaker, "Secure Shell Transport Model for the Simple Network Management Protocol (SNMP)", RFC 5592, June 2009. [RFC6353] Hardaker, W., "Transport Layer Security (TLS) Transport Model for the Simple Network Management Protocol (SNMP)", RFC 6353, July 2011. [RFC7143] Chadalapaka, M., Satran, J., Meth, K., and D. Black, "Internet Small Computer System Interface (iSCSI) Protocol (Consolidated)", RFC 7143, April 2014. Bakke & Venkatesen Standards Track [Page 90] RFC 7147 iSCSI MIB April 2014 [RFC7144] Knight, F. and M. Chadalapaka, "Internet Small Computer System Interface (iSCSI) SCSI Features Update", RFC 7144, April 2014. 10.2. Informative References [RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart, "Introduction and Applicability Statements for Internet- Standard Management Framework", RFC 3410, December 2002. [RFC4022] Raghunarayan, R., Ed., "Management Information Base for the Transmission Control Protocol (TCP)", RFC 4022, March 2005. [RFC4455] Hallak-Stamler, M., Bakke, M., Lederman, Y., Krueger, M., and K. McCloghrie, "Definition of Managed Objects for Small Computer System Interface (SCSI) Entities", RFC 4455, April 2006. [RFC4544] Bakke, M., Krueger, M., McSweeney, T., and J. Muchow, "Definitions of Managed Objects for Internet Small Computer System Interface (iSCSI)", RFC 4544, May 2006. 11. Acknowledgments The contents of this document were largely written as RFC 4544 by Mark Bakke (Cisco), Marjorie Krueger (Hewlett-Packard), Tom McSweeney (IBM), and James Muchow (QLogic). A special thank you to Marjorie, Tom, and James for their hard work and especially to James for his attention to detail on this work. In addition to the authors, several people contributed to the development of this MIB module. Thanks especially to those who took the time to participate in our weekly conference calls to build our requirements, object models, table structures, and attributes: John Hufferd, Tom McSweeney (IBM), Kevin Gibbons (Nishan Systems), Chad Gregory (Intel), Jack Harwood (EMC), Hari Mudaliar (Adaptec), Ie Wei Njoo (Agilent), Lawrence Lamers (SAN Valley), Satish Mali (Stonefly Networks), and William Terrell (Troika). Special thanks to Tom McSweeney, Ie Wei Njoo, and Kevin Gibbons, who wrote the descriptions for many of the tables and attributes in this MIB module, to Ayman Ghanem for finding and suggesting changes for many problems in this module, and to Keith McCloghrie for serving as advisor to the team. Thanks to Mike MacFaden (VMWare), David Black (EMC), and Tom Talpey (Microsoft) for their valuable inputs. Bakke & Venkatesen Standards Track [Page 91] RFC 7147 iSCSI MIB April 2014 Authors' Addresses Mark Bakke Dell 7625 Smetana Lane Eden Prairie, MN 55344 USA EMail: mark_bakke@dell.com Prakash Venkatesen HCL Technologies Ltd. 50-53, Greams Road, Chennai - 600006 India EMail: prakashvn@hcl.com Bakke & Venkatesen Standards Track [Page 92]